TSE-P 02.00 EB
45/60
599 35 24-30
7.6 Reading the last alarm condition
The diagnostics system makes it possible to identify the last alarm condition which occurred during the
operation of the appliance. To read this alarm condition, after accessing the diagnostics system (see
"Access to the diagnostics / configuration system), press the FABRICS or TEMPERATURE buttons until
LED
L9
lights.
The alarm condition is shown on the display, or the corresponding binary code flashes on the wash phase
LEDs.
Ö
The first four LEDs indicate the first digit of the alarm code
Ö
The second four LEDs indicate the second digit of the alarm code
For example, if an
E41
alarm condition (door open) is generated, the display will show
E41
or (if the
appliance does not feature the display window) the second LED in the first group (equivalent to
4
in binary
code) and the fourth LED in the second group (equivalent to
1
in binary code) will flash.
If no alarm condition has occurred,
E00
is displayed.
7.6.1
Diagnostics cycle alarms
If a malfunction should occur during the course of the diagnostics cycle, the relative alarm codes are
displayed. In this case, too, the wash phase LEDs (or the display) show the error code (flashing).
Binary codes
The table below shows how to convert the binary code displayed by the LEDs into the corresponding
decimal number.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
A
b
C
d
E
F
❍
❍
❍
❍
❍
❍
❍
❍
●
●
●
●
●
●
●
●
❍
❍
❍
❍
●
●
●
●
❍
❍
❍
❍
●
●
●
●
❍
❍
●
●
❍
❍
●
●
❍
❍
●
●
❍
❍
●
●
❍
●
❍
●
❍
●
❍
●
❍
●
❍
●
❍
●
❍
●
❍
LED
off
●
LED
on