AOS OVENS - Service Manual
(595889300 – ENG)
Using the pressure inlet signed with “
–
” and with negative reading on the display as in the fig.31-32, this
means we are measuring
+ 0.16 hPa = + 16 Pa
:
Using the pressure inlet signed with “
–
” and with positive reading on the display as in the fig. 33-34, this
means we are measuring
– 0.16 hPa = – 16 Pa
:
Fig. 31
Fig. 32
Fig. 33
Fig. 34
14. Change of the microprocessor board
In case of changing of the microprocessor board, the following operations/calibrations have to be done:
1) Default parameter programming
2) Change parameters according parameter list
3) Lambda probe calibration for lev. A ovens (from firmware 2.6)
4) By-pass calibration (lev. B ovens) and cavity offset (parameter
OCA1
) or only cavity offset for lev. A
ovens.
File: AOS service manual (ENG).008