9.2.
Utilities that can be activated in parameter programming
•
Pressing the steam cycle and hot air cycle buttons, all the output relays are sequentially activated and
on the time display it will be displayed the activated relay with the message
do1
,
do2
, ... (
dox
=
RLx
on
the EWD)
From firmware release 2.7 this utility is changed as follows:
o
The steam cycle button acts as main switch: if it is released, the test stops.
o
Each time the hot air cycle button is pressed, the next relay is activated and remains activated till
the next pressure of the hot air cycle button.
o
If the hot air cycle button is kept pressed, the relays are sequentially activated.
•
Pressing the time buttons, the time will be displayed
•
Pressing the utility button, on the time display a 4-characters message will be displayed while on the
little display will be shown a number with the following meanings
Big display
Meaning of the number on the little display
PCB temperature
ntc
First meat probe temperature (lev. A)
Prb1
Second meat probe temperature (lev. A)
Prb2
Third meat probe temperature (lev. A)
Prb3
Fourth meat probe temperature (lev. A)
Prb4
File: AOS service manual (ENG).008