background image

         

14

NB (for models with on board unit):

 appliances with unit on

board must be handled in the upright position.
If the equipment is handled in a horizontal position, make sure
to wait a few hours before operating it.  This is to give the oil time

to settle.

 

CAUTION:

Do not push or pull the appliance to move it, as it may tip over.

B.1.2.2  Disposing of the packaging

Packaging materials should be disposed of in accordance to
the binding laws in the country where the appliance is to be used.

Recyclable plastic parts are marked as follows:

  polythene:

 outer wrapping, instructions booklet bag

PE

    polypropylene:

 straps

PP

   polystyrene foam: 

corner pads

PS

B.1.3 POSITIONING

Install the equipment, taking all the safety precautions
required for this type of operation, also respecting the
relevant fire-prevention instructions.

Place the appliance in a ventilated room and away from
heat sources such as radiators or air-conditioning
systems,  in order to allow the cooling of the refrigerating

unit components.
Never cover the condenser, not even temporarily, as
this may jeopardise the operation of both the condenser and the

appliance.
Should the appliance be installed in rooms where there are
corrosive substances (chlorine, etc.), it is advisable to wipe over

all the stainless steel surfaces with a cloth coated with vaseline
oil to create a protective film.
The room temperature should not exceed 89.6°F/+32°C in order

to maintain the recommended internal temperatures.  Make
sure to position the appliance at least 1.97"/50mm from any
machines present in the room (in fact, close proximity can create

problems of condensation forming on the walls of the appliance),
also taking into consideration the space needed for door opening.

              

Pay particular attention to levelling of the floor on which the

appliance stands, in order to ensure its optimal operation.

 

IMPORTANT:

Level the appliance,  otherwise its operation could be com-
promised.

Adjust the height and level the appliance by means of the
leveling feet, checking that the door opens and closes properly.

+50 mm
 + 1.97 "

-10 mm
 - 0.39 "

B.1.3.1 Installation of the condensation tray (see pict. 1- 5)

             

           

2

1

Содержание AOFP061U

Страница 1: ...nstallation of the condensation tray Page 14 B 1 3 2 Positioning the spacers Page 14 B 1 3 3 Positioning on the Cook Chill stacked units Page 15 B 1 3 4 Positioning the top Page 16 B 1 4 Draining the water Page 16 B 1 4 1 Manual draining Page 16 B 1 4 2 Automatic draining Page 16 B 1 5 Positioning appliances arranged for use with remote units and positioning of condensing units Page 18 B 1 6 Elect...

Страница 2: ...de practices BEFORESERVICING DISCONNETTHEELECTRICALSERVICE ANDPLACEAREDTAGATTHEDISCONNECT SWITCH TO INDICATE WORK IS BEING DONE ON THAT CIRCUIT NOTICE CONTACTYOUR AUTHORIZEDSERVICECOMPANYTOPERFORMMAINTENANCEANDREPAIRS NOTICE Usinganypartsotherthangenuinefactorymanufacturedpartsrelievesthemanufacturerofallwarrantyand liability NOTICE Manufacturer reserves the right to change specifications at any t...

Страница 3: ...nd after installation Read the instructions in the manual carefully before carrying out anyoperationwhatsoeverontheappliance astheygiveimportant information about the standards and rules governing its installation and safe use Improper installation adjustment alteration service or maintenance can cause property damage injury or death Failure to observe the instructions in this manual when carrying...

Страница 4: ...s which require air movement WEARPROTECTIVEGLOVESWHENUNPACKING ANDINSTALLINGTHEAPPLIANCE Read these instructions carefully before attempting installation Installation and initial startup should be performed by a qualified installer Unless the installation instructions for this product are followed by a qualified service technician a person experienced in and knowledgable with the installation of c...

Страница 5: ...g it to avoid leaving glue stuck to the surface Should this happen remove the traces of glue with a non corrosive solvent rinsing it off and drying carefully It is advisable to go over all the stainless steel surfaces with a cloth coated with vaseline oil in order to form a protective film Use a pallet jack or fork lift truck to lift appliances Inserting the forks under the pallet lift the applian...

Страница 6: ...ng of the refrigerating unit components Never cover the condenser not even temporarily as this may jeopardise the operation of both the condenser and the appliance Should the appliance be installed in rooms where there are corrosive substances chlorine etc it is advisable to wipe over all the stainless steel surfaces with a cloth coated with vaseline oil to create a protective film The room temper...

Страница 7: ... screws screwing them into the mounting holes The spacers have the function of keeping the appliance a certain distance from the wall to allow the refrigerating unit elements to cool properly Failure to install the spaces will void warranty and any responsibility of the manufacturer B 1 3 3 Positioning of the Cook Chill stacked units If the AOFP061U blast freezer will be used to make a new a Cook ...

Страница 8: ... 4Positioningthetop If the AOFP061U chiller is not to be stacked on the Cook Chill unit order and fit the top kit code F880027 To fit the top follow the instructions given below making reference to the steps illustrated take the hinge and fit it to the top of the chiller externally on the left using the supplied M5X12 screws see picture A position the polysterol cover see picture B position the to...

Страница 9: ...AOFP101U and AOFP102U models periodic emptying of the liquid drain tray can be avoided by connecting the chamber drain located on the bottom of the appliance to a drainage system or by connecting a hose to the drain and running the water into a floor grate For AOFP201RU models periodic emptying of the liquid drain tray can be avoided by connecting the cell drain located on the evaporator tray to a...

Страница 10: ...THREMOTEUNITSANDPOSITIONINGOFCONDENSING UNITS Important theoperationmustbecarriedoutbyprofessionally qualifiedpersonnel Install the unit following all safety measures required for this type of operation Place the condenser unit in a well ventilated room a long way from heat sources If the remote unit is to be installed outdoors it must be protected against natural elements with a cover which must ...

Страница 11: ...r injury resulting from the violation of the above rules or of the binding electrical safety standards in the country where the appliance is used B 1 7PUTTINGTHELINESUNDERVACUUMANDCHARGING WITHREFRIGERANTGAS FORREMOTEUNITS B 1 7 1 Leakage test Wash out the intake pipes with pressurised dry nitrogen Connect a nitrogen cylinder to the high and low pressure connectors and connect to a pressure gauge ...

Отзывы: