background image

         

12

4 - AOFP201RU blast freezers (for use with remote unit)

External dimensions:
Width

40.94"

1040 mm

Depth with door closed

37.60"

 955 mm

Depth with door open

55.96"

 1421.5 mm

Height

70.20"

 1783 mm

Cell dimensions:
Width

20.69"

 525.5 mm

Depth

27.75"

 705 mm

Height

57.20"

 1453 mm

Productivity (according to specifications) (*):
Minutes

120 minutes

Pounds

220.46lbs/100Kg

PANS:
20" x 25" x 2 1/2"

530mm x 650mm x 65mm.
Number of pans

20

18" x 26"
457.2mm x 660.4mm
Number of Pans

20

Power supply voltage

208V/3ph/60HZ

Total Power

1440 watts

Refrigerant type

R404A

No. of defrostings in 24 hours 3
High side design pressure

370psig

Low side design pressure

174psig

(*) The total weight of the chilled product has been placed on the

pans with a height 1.57"/40 mm.  Unit running at 100.4°F (+38°C)
ambient temperature.  Following NSF rule number seven (7), the
product has been chilled from 140°F /60°C to 39.2°F /4°C in

shown minutes.

Maximum room temperature:

100.4°F/+38°C

Thermostatic valve (i.e.type DANFOSS)

type

067B4004

Orifice for valve (i.e.type DANFOSS)

type

067B2089

Thermostatic element (i.e.type DANFOSS) type

067B3358

RECOMMENDED COOLING UNIT SPECIFICATIONS

FOR CUSTOMER SUPPLIED COMPRESSOR

 Refrigerant power HMBP [W]

17000

 condensation temp. at 113°F/+45°C

 evaporation temp. at 23°F/-5°C

 suction gas temp. at 68°F/20°C

 without liquid subcooling

 Refrigerant power HMBP [W]

9050

 condensation temp. at

 

113°F/+45°C

 evaporation temp. at -4°F/-20°C

 suction gas temp. 68°F/20°C
 without liquid subcooling

 Refrigerant power HMBP [W]

5570

 condensation temp. 113°F/+45°C

 evaporation temp. at -22°F/-30°C

 suction gas temp. at 68°F/20°C

 without liquid subcooling

A.2.3 PHYSICAL SAFETY FEATURES, HAZARDS

The appliance has no sharp or projecting parts.

DANGER! DO NOT REMOVE.

 There are guards on the units to

prevent access to components which require air movement.

WEAR PROTECTIVE GLOVES WHEN UNPACKING
AND INSTALLING THE APPLIANCE.

Read these instructions carefully before
attempting installation.  Installation and initial startup should be
performed by a qualified installer.  Unless the installation

instructions for this product are followed by a qualified service
technician (a person experienced in and knowledgable with the
installation of commercial equipment) then the terms and

conditions on the Manufacturer's  Warranty will be rendered void
and no warranty of any kind shall apply.

IF IN DOUBT PLEASE CONTACT LOCAL SERVICE
AGENCY.

B.1.1  IMMEDIATELY INSPECT FOR SHIPPING DAMAGE

The container should be examinded for damage before and

during unloading.  The freight carrier  has assumed responsibility
for its safe transit and delivery.  If damaged equipment is
received, either apparent or concealed, a claim must be made

with the delivering carrier.  Apparent damage or loss must be
noted on the freight bill at the time of delivery.  The freight bill must
then be signed by the carrier representative (Driver).  If the bill

is not signed, the carrier may refuse the claim. The supply can
supply the necessary forms.  A request for inspection must be
made to the carrier within 15 days if there is concealed damage

or loss that is not apparent until after the equipment is uncrated.
The carrier should arrange an inspection.  Be certain to hold all
contents plus all packing material.  Under no circumstances

should a damaged appliance be returned to the manufacturer
without prior notice and written authorization.

 

CAUTION:

The operations described below should be carried out in

compliance with current safety regulations, with reference
both to the equipment used and the operating procedures.
IMPORTANT:  Before moving the appliance, make sure that

the load-bearing capacity of the lifting equipment to be used
is suitable for the weight of the appliance.

B.1.2  REMOVING  THE  PACKAGING (see picture 1)

                             

FIG.1

 B.1 INSTALLATION

1

Содержание AOFP061U

Страница 1: ...nstallation of the condensation tray Page 14 B 1 3 2 Positioning the spacers Page 14 B 1 3 3 Positioning on the Cook Chill stacked units Page 15 B 1 3 4 Positioning the top Page 16 B 1 4 Draining the water Page 16 B 1 4 1 Manual draining Page 16 B 1 4 2 Automatic draining Page 16 B 1 5 Positioning appliances arranged for use with remote units and positioning of condensing units Page 18 B 1 6 Elect...

Страница 2: ...de practices BEFORESERVICING DISCONNETTHEELECTRICALSERVICE ANDPLACEAREDTAGATTHEDISCONNECT SWITCH TO INDICATE WORK IS BEING DONE ON THAT CIRCUIT NOTICE CONTACTYOUR AUTHORIZEDSERVICECOMPANYTOPERFORMMAINTENANCEANDREPAIRS NOTICE Usinganypartsotherthangenuinefactorymanufacturedpartsrelievesthemanufacturerofallwarrantyand liability NOTICE Manufacturer reserves the right to change specifications at any t...

Страница 3: ...nd after installation Read the instructions in the manual carefully before carrying out anyoperationwhatsoeverontheappliance astheygiveimportant information about the standards and rules governing its installation and safe use Improper installation adjustment alteration service or maintenance can cause property damage injury or death Failure to observe the instructions in this manual when carrying...

Страница 4: ...s which require air movement WEARPROTECTIVEGLOVESWHENUNPACKING ANDINSTALLINGTHEAPPLIANCE Read these instructions carefully before attempting installation Installation and initial startup should be performed by a qualified installer Unless the installation instructions for this product are followed by a qualified service technician a person experienced in and knowledgable with the installation of c...

Страница 5: ...g it to avoid leaving glue stuck to the surface Should this happen remove the traces of glue with a non corrosive solvent rinsing it off and drying carefully It is advisable to go over all the stainless steel surfaces with a cloth coated with vaseline oil in order to form a protective film Use a pallet jack or fork lift truck to lift appliances Inserting the forks under the pallet lift the applian...

Страница 6: ...ng of the refrigerating unit components Never cover the condenser not even temporarily as this may jeopardise the operation of both the condenser and the appliance Should the appliance be installed in rooms where there are corrosive substances chlorine etc it is advisable to wipe over all the stainless steel surfaces with a cloth coated with vaseline oil to create a protective film The room temper...

Страница 7: ... screws screwing them into the mounting holes The spacers have the function of keeping the appliance a certain distance from the wall to allow the refrigerating unit elements to cool properly Failure to install the spaces will void warranty and any responsibility of the manufacturer B 1 3 3 Positioning of the Cook Chill stacked units If the AOFP061U blast freezer will be used to make a new a Cook ...

Страница 8: ... 4Positioningthetop If the AOFP061U chiller is not to be stacked on the Cook Chill unit order and fit the top kit code F880027 To fit the top follow the instructions given below making reference to the steps illustrated take the hinge and fit it to the top of the chiller externally on the left using the supplied M5X12 screws see picture A position the polysterol cover see picture B position the to...

Страница 9: ...AOFP101U and AOFP102U models periodic emptying of the liquid drain tray can be avoided by connecting the chamber drain located on the bottom of the appliance to a drainage system or by connecting a hose to the drain and running the water into a floor grate For AOFP201RU models periodic emptying of the liquid drain tray can be avoided by connecting the cell drain located on the evaporator tray to a...

Страница 10: ...THREMOTEUNITSANDPOSITIONINGOFCONDENSING UNITS Important theoperationmustbecarriedoutbyprofessionally qualifiedpersonnel Install the unit following all safety measures required for this type of operation Place the condenser unit in a well ventilated room a long way from heat sources If the remote unit is to be installed outdoors it must be protected against natural elements with a cover which must ...

Страница 11: ...r injury resulting from the violation of the above rules or of the binding electrical safety standards in the country where the appliance is used B 1 7PUTTINGTHELINESUNDERVACUUMANDCHARGING WITHREFRIGERANTGAS FORREMOTEUNITS B 1 7 1 Leakage test Wash out the intake pipes with pressurised dry nitrogen Connect a nitrogen cylinder to the high and low pressure connectors and connect to a pressure gauge ...

Отзывы: