11.11 Solenoid
valves
This component introduces water into the detergent dispenser and is controlled electrically by the main circuit board
via Triac. The level of water in the tub is controlled by the analogue pressure switch.
1. Water
inlet
2. Solenoid
valve
body
3. Filter
4. Flow
reducer
5. Coil
6. Spring
7. Moving
core
8. Rubber
9. Membrane
10. Water outlet
11.11.1 Operating
principle
When idle, the core, pushed by a spring, keeps the central hole of the membrane closed and so the latter hermetically
seals access to the water inlet duct.
When the coil is powered, the core is attracted, releasing the central hole of the membrane. Consequently the valve
opens.
1. Main circuit board
2. Door safety interlock
6. Pre-wash
solenoid
7. Wash
solenoid
8. Steam solenoid valve
9.
Hot water solenoid