TABLE OF ALARM CONDITIONS
The table below shows the meanings of the various Alarm Codes which may appear in the
DIGIT
window
and the possible causes of each.
ALARM CODE
TIME-OUT
POSSIBLE CAUSES
A
WATER FILL
Maximum duration 5 minutes
- Tap closed
- Mains water pressure too low
- Fill hose filter obstructed
- Solenoid valve inoperative
- Siphon effect in drain hose
- Intervention of anti-overflow device
- Intervention of anti-flooding device
- Control board faulty
C
SUPPLEMENTARY FILL
Maximum duration 45 seconds
(overall time)
- Leaks from sump or sump couplings
- Siphon effect in drain hose
- Circular filter obstructed
- Dishes upside-down
- Pressure switch faulty
- Leaks from pressure switch tube
- Control board faulty
F
PRESSURE SWITCH "EMPTY"
(waiting for temperature)
Maximum duration 2 minutes
not more than 3 times
- Leaks from sump or sump couplings
- Siphon effect in drain hose
- Circular filter obstructed
- Dishes upside-down
- Pressure switch faulty
- Leaks from pressure switch tube
- Control board faulty
L
TEMPERATURE SENSOR
Instantaneous intervention
during the heating phase
Operating range: -5° to 85°C
- Temperature sensor interrupted or out of range
- Connections loose/interrupted
- Temperature sensor incorrectly positioned
- Temperature sensor short-circuited
- Connections short-circuited
- Temperature in excess of 85°C
- Control board faulty
H
WATER HEATING
Maximum duration 45 minutes
excluding drying phase
- Heating element interrupted
- Connections interrupted
- Safety thermostat open
- Temperature sensor incorrectly calibrated or not in position
(poor contact)
- Circular filter obstructed
- Water level too low
- Upper spray arm jammed
- Control board faulty
P
PRESSURE SWITCH "EMPTY"
(end of drain)
Instantaneous intervention at the
end of each drain phase
- Drain pump inoperative
- Drain hose kinked
- Chamber drain siphon inoperative
- Recirculation hose obstructed or incorrectly positioned
- Pressure switch blocked on "full" (1 - 3)
- Control board faulty
- 44 -
Содержание 60 cm Series
Страница 2: ... 2 ...
Страница 8: ...STRUCTURE 8 ...
Страница 9: ...INTERIOR OF TUB SUMP 9 ...
Страница 10: ...HYDRAULIC ELECTRICAL COMPONENTS 10 ...
Страница 15: ...WATER FILL CIRCUIT 15 ...
Страница 17: ...LEVEL CONTROL CIRCUIT 17 ...
Страница 19: ...WATER SOFTENING CIRCUIT 19 ...
Страница 21: ...REGENERATION SYSTEM CIRCUIT DIAGRAM 21 ...
Страница 28: ...FUNCTIONAL CIRCUIT DIAGRAM STANDARD TIMER 28 ...
Страница 29: ...TIMER OPERATION STANDARD 29 ...
Страница 30: ...FUNCTIONAL CIRCUIT DIAGRAM MEDIUM DE LUXE TIMER 30 ...
Страница 31: ...TIMER OPERATION MEDIUM DE LUXE 31 ...
Страница 34: ...FUNCTIONAL CIRCUIT DIAGRAM ITRONIC 34 ...
Страница 35: ...CYCLE SEQUENCE ITRONIC 35 ...