WATER FILL
Time-out
- The maximum duration of the water fill phase
is
5 minutes
.
- The
time-out
counter starts at the beginning
of each fill phase, and ends when a "full" signal
is received from the pressure switch (
1 - 3
).
- If the time required for the pressure switch
to reach "full" condition (
1 - 3
) is more than
5 minutes
, an alarm condition is generated.
SITUATION
Appliance:
STOPPED
When the door is opened:
DIGIT
window:
A
(flashing)
LEDs:
OFF
SUPPLEMENTARY FILL
Time-out
- The maximum duration of the supplementary
water fill phase after the pressure switch has
been reset is
45 seconds
.
- The
time-out
safety system becomes operative
when the water level is reached (pressure
switch "full"
1 - 3
) and remains in operation
until the subsequent drain phase.
- The
time-out
counter starts as soon as
the pressure switch is reset to "empty" (
1 - 2
)
and ends when the pressure switch returns
to "full" (
1 - 3
).
- If the time required for the pressure switch
to return to the "full" condition (
1 - 3
) is more
han
45 seconds
, an alarm condition is generated.
- If more than one supplementary fill is performed
because the pressure switch returns more
than once to "empty" (
1 - 2
), the total duration
of the supplementary fill phases must not
exceed
45 seconds
. If this occurs, an alarm
condition is generated.
SITUATION
Appliance:
STOPPED
When the door is opened:
DIGIT
window:
C
(flashing)
LEDs:
OFF
- 41 -
Содержание 60 cm Series
Страница 2: ... 2 ...
Страница 8: ...STRUCTURE 8 ...
Страница 9: ...INTERIOR OF TUB SUMP 9 ...
Страница 10: ...HYDRAULIC ELECTRICAL COMPONENTS 10 ...
Страница 15: ...WATER FILL CIRCUIT 15 ...
Страница 17: ...LEVEL CONTROL CIRCUIT 17 ...
Страница 19: ...WATER SOFTENING CIRCUIT 19 ...
Страница 21: ...REGENERATION SYSTEM CIRCUIT DIAGRAM 21 ...
Страница 28: ...FUNCTIONAL CIRCUIT DIAGRAM STANDARD TIMER 28 ...
Страница 29: ...TIMER OPERATION STANDARD 29 ...
Страница 30: ...FUNCTIONAL CIRCUIT DIAGRAM MEDIUM DE LUXE TIMER 30 ...
Страница 31: ...TIMER OPERATION MEDIUM DE LUXE 31 ...
Страница 34: ...FUNCTIONAL CIRCUIT DIAGRAM ITRONIC 34 ...
Страница 35: ...CYCLE SEQUENCE ITRONIC 35 ...