Electrolux 318201778 Скачать руководство пользователя страница 2

2

36" GAS RANGE INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY
INSTRUCTIONS

Installation of this range must conform with local codes
or, in the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1/NFPA No.54.

When installing in a manufactured (mobile) home,
installation must conform with Manufactured Home
Construction and Safety Standard, title 24CFR, part 3280
[Formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD (part 280)] or,
when such standard is not applicable, the Standard for
Manufactured Home Installation, ANSI Z225.1/NFPA
501A-latest edition, or with CAN/CSA-Z240 MH, or with
local codes .

This range has been design certified by CSA
international. As with any appliance using gas and
generating heat, there are certain safety precautions you
should follow. You will find them in the Use and Care
Guide, read it carefully.

• Be sure your range is installed and grounded

properly by a qualified installer or service
technician.

• This range must be electrically grounded in

accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70—latest edition in the United States or with CSA
standard C22.1, Canadian Electrical Code, Part 1 in
Canada

.

• Make sure the wall coverings around the range

can withstand the heat generated by the range.

• Before installing the range in an area covered

with linoleum or any other synthetic floor
covering, make sure the floor covering can
withstand heat at least 90°F/32°C above room
temperature without shrinking, warping or
discoloring.

 Do not install the range over carpeting

unless you place an insulating pad or sheet of 1/4" (6.4
mm) thick plywood between the range and carpeting.

• Do not obstruct the flow of combustion air at the

oven vent nor around the base or beneath the
lower front panel of the range.

 Avoid touching the

vent openings or nearby surfaces as they may become
hot while the oven is in operation. This range requires
fresh air for proper burner combustion.

 Never leave children alone or

unattended in the area where an appliance is in use.

As children grow, teach them the proper, safe use of all
appliances. Never leave the oven door open when the
range is unattended.

 Stepping, leaning or sitting on the

door of this range can result in serious injuries and
can also cause damage to the range.

• Do not store items of interest to children in the

cabinets above the range.

 Children could be seriously

burned climbing on the range to reach items.

• To eliminate the need to reach over the surface

units, cabinet storage space above the units
should be avoided.

• Adjust surface burner flame size so it does not

extend beyond the edge of the cooking utensil.

Excessive flame is hazardous.

Do not use the oven as a storage space. 

This

creates a potentially hazardous situation.

• Never use your range for warming or heating the

room.

 Prolonged use of the range without adequate

ventilation can be dangerous.

• Do not store or use gasoline or other flammable

vapors and liquids near this or any other
appliance. 

Explosions or fires could result.

In the event of an electrical power outage, the surface

burners can be lit manually. To light a surface burner,
hold a lit match to the burner head and rapidly turn the
Surface Control knob to Med. Use caution when
lighting surface burners manually.

• Remove broiler pan, food and other utensils

before self-cleaning the oven. 

Wipe up excess

spillage. Follow the cleaning instructions in the Use &
Care Guide.

• Unlike the standard gas range, THIS COOKTOP IS

NOT REMOVABLE. 

Do not attempt to remove the

cooktop.

Special Instructions for appliances installed in the State of
Massachusetts: This appliance can only be installed in the
State of Massachusetts by a Massachusetts licensed
plumber or gas fitter. When using a flexible gas
connector, it must not exceed 3 feet (36 inches) in
length. A "T" handle type manual gas valve must be
installed in the gas supply line to this appliance.

• All ranges can

tip.

• Injury to

persons could
result.

• Install anti-tip

device packed
with range.

 To reduce

the risk of tipping of the range,
the range must be secured by
properly installed anti-tip
bracket(s) provided with the
range. To check if the bracket is
installed properly, grasp the top
rear edge of the range and
carefully tilt it forward to make
sure the range is anchored.

 

Never 

cover any slots, holes or passages

in the oven bottom or cover an entire rack with materials
such as alminum foil. Doing so blocks air flow through
the oven and may cause carbon monoxide poisoning.
Aluminum foil linings may also trap heat, causing a fire
hazard.

Содержание 318201778

Страница 1: ...TRUCTIONS FOR FUTURE REFERENCE OBSERVE ALL GOVERNING CODES AND ORDINANCES Note For appliances installed in the state of Massachusetts see page 2 Refer to your serial plate for applicable agency certification NOTE 28 71 1 cm minimum clearance between the cooktop and the bottom of the cabinet when the bottom of wood or metal cabinet is protected by not less than 1 4 0 64 cm flame retardant millboard...

Страница 2: ...unattended Stepping leaning or sitting on the door of this range can result in serious injuries and can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminate the need to reach over the surface units cabinet storage space above the units should be avoided Adjust s...

Страница 3: ...ve or bypass the grounding prong Power supply cord with 3 prong grounding plug Figure 2 2 Electrical Requirements 120 volt 60 Hertz properly grounded dedicated circuit protected by a 15 amp circuit breaker or time delay fuse Note This range is not recommended to be installed with a Ground Fault Interrupt GFI Do not use an extension cord with this range Grounding Instructions IMPORTANT Please read ...

Страница 4: ...ak and possible fire or explosion The gas supply line to the shutoff valve should be 1 2 1 27 cm or 3 4 1 9 cm solid pipe The user must know the location of the main shutoff valve and have easy access to it When using flexible gas conduit on the range allow sufficient slack to pull the range outside the cutout for cleaning or servicing NOTE Do not allow the flexible conduit to get pinched between ...

Страница 5: ...er heated surface units cabinet storage space located above the range should be avoided If cabinet storage space is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinet Figure 5 Follow instructions for the type of installation you have Center Line of Range If range will be installed with a cabinet on bo...

Страница 6: ...normal operation after air has been purged from supply lines Visually check that burner has lit c Once the burner lights the control knob should be rotated out of the LITE position There are separate ignition devices for each burner Try each knob separately until all burner valves have been checked Regular Burner Burner Cap Fixed Burner Ring and Burner Base Dual Surface Burner Burner Base Fixed Bu...

Страница 7: ...igure 8 4 Adjust the LOW Setting of Regular Burner see figure 7 on the Surface Burner Valves Figure 8 a Push in and turn control to LITE until burner ignites b Quickly turn knob to LOWEST POSITION c If burner goes out reset control to OFF d Remove the surface burner control knob and decorative ring e Insert a thin bladed screwdriver into the hollow valve stem and engage the slotted screw inside Fl...

Страница 8: ...anti tip brackets are engaged Important Safety Warning To reduce the risk of tipping of the range the range must be secured to the floor by the properly installed anti tip bracket and screws packed with the range These parts are located in a plastic bag in the oven This gas range has two brackets Failure to install the bracket will allow the range to tip over if excessive weight is placed on an op...

Страница 9: ...la agencia de servicio o el proveedor de gas Nota Para electrodomésticos instalados en el estado de Massachussets Vea página 12 P N 318201778 0809 Rev A English pages 1 8 Español páginas 9 16 Notas páginas 17 19 Diagrama de la instalación alámbrica página 20 G F 13 Max 33 cm Max 35 7 8 Mín 91 1 cm Mín PARED PARED 18 Mín 45 7 cm Mín A B C D E NOTA Un espacio mínimo de 28 71 1 cm entre la superficie...

Страница 10: ...ard for Mobil Home Construction and Safety título 24 HUD parte 280 o cuando tal estándar no se aplica el Standard for Manufactured Home Installation 1982 Manufactured Home sites Communities and Setups ANSI Z225 1 NFPA 501A edición más reciente o con los códigos locales Esta estufa ha sido diseñada y certificada por el organismo CSA Internacional Como en cualquier electrodoméstico donde se use gas ...

Страница 11: ...ufe de pared con toma de tierra Figura 2 2 Requisitos eléctricos 120 voltio 60 Hertzio circuito dedicado apropiadamente puestos a tierra protegido por un circuito de amperio o fusible de demora de tiempo de 15 amp Nota no es recomendado instalarlo con un Interruptor GFI de puesta a tierra No utilice una extensión con esta estufa Instrucciones de puesta a tierra IMPORTANTE Por favor lea con cuidado...

Страница 12: ...onector codo de 90o Monte el conector flexible desde el tubo de suministro de gas hasta el conector T de gas según este orden 1 Válvula de cierre manual no incluido 2 Conector flexible no incluido 3 Conector codo de 90o no incluido 4 Conector T de gas incluido Conector T de gas Conexión del regulador El regulador esta instalado en el electrodoméstico Asegurese de no apretar demasiado la conexión E...

Страница 13: ...nter Line of Range Si la estufa se va a instalar con armarios laterales marque el centro de la abertura del armario en el piso ver la figura 5 Si la parte trasera de la estufa no estará a ras con la pared la ubicación del tomacorriente puede que no permita que la estufa se pegue a ras con la pared marque el piso donde estará el border trasero de la estufa Ponga el patrón en el piso alineando la lí...

Страница 14: ...sición LITE Cada quemador tiene su encendedor individual Controle las perillas separadamente hasta que todas las válvulas hayan sido controladas 4 Ajuste bajo LO para la válvula de los quemadores de superficie estandar Figuras 7 y 8 a Presione y gire el control hasta la posición LITE para prender los quemadores 6 Instalación de la estufa 1 La parte trasera de la estufa puede ser directamente insta...

Страница 15: ... a la POSICIÓN MÁS BAJA c Si el quemador se apaga reajuste el control a OFF d Retire la perilla del quemador de superficie Figura 9 e El tamaño de la flama de la porción posterior del quemador puente puede aumentarse o disminuirse dándole vuelta al tornillo A vea Figura 9 Utilice el tornillo B para ajustar el tamaño de la llama de la porción central del quemador puente o del quemador triple Dé vue...

Страница 16: ...este instalada utilice el diagrama en el cuadro 10 para situar el soporte si la plantilla no está disponible 4 Marque en el piso la localización de los agujeros de montaje demostrados en la plantilla posición derecha y izquierda Para una instalación más fácil los agujeros 1 2 1 3 centímetros de diámetro y 3 16 4 8 milímetros de profundidad pueden perforarse en el piso 5 Quite la plantilla y coloqu...

Страница 17: ...17 NOTES NOTAS ...

Страница 18: ...18 NOTES NOTAS ...

Страница 19: ...19 NOTES NOTAS ...

Страница 20: ...WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA 20 ...

Отзывы: