36" GAS RANGE INSTALLATION INSTRUCTIONS

1.

 Model and Serial Number Location

The serial plate is located at back of the appliance.

When ordering parts for or making inquires about your
oven, always be sure to include the model and serial
numbers and a lot number or letter from the serial plate
on your oven.

Figure 1

Serial plate

location

Gas Connector

Important Notes to the Installer

1.

Read all instructions contained in these installation
instructions before installing range.

2.

Remove all packing material from the oven
compartments before connecting the electrical supply
to the range.

3.

Observe all governing codes and ordinances.

4.

Be sure to leave these instructions with the consumer.

5.

Note: For operation at 2000 ft. elevations above see
level, appliance rating shall be reduced by 4 percent
for each  additional 1000 ft.

Important Note to the Consumer

Keep these instructions with your owner's guide for future
reference.

Optional Items Available:

A Stainless Steel Kick Plate

A Black Knob Kit

Those kits can be ordered for purchase through an Electrolux
Service Center at 1-877-4ELECTROLUX (1-877-435-3287).

Preferred Method

Grounding type
wall receptacle

Do not, under any
circumstances, cut,
remove, or bypass
the grounding
prong.

Power supply cord with 3-
prong grounding plug.

Figure 2

2.  

Electrical Requirements

120 volt, 60 Hertz, properly grounded dedicated circuit
protected by a 15 amp circuit breaker or time delay fuse.

Note: 

This range is not recommended to be installed

with a Ground Fault Interrupt (GFI).

Do not use an extension cord with this range.

Grounding Instructions

IMPORTANT

 Please read carefully.

For personal safety, this appliance must be properly
grounded.

The power cord of this appliance is equipped with a 3-
prong (grounding) plug which mates with a standard 3-
prong grounding wall receptacle (see Figure 2) to
minimize the possibility of electric shock hazard from the
appliance.

The wall receptacle and circuit should be checked by a
qualified electrician to make sure the receptacle is
properly grounded.
Where a standard 2-prong wall receptacle is installed, it
is the personal responsibility and obligation of the
consumer to have it replaced by a properly grounded 3-
prong wall receptacle.

Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.

 

Disconnect electrical supply cord from

wall receptacle before servicing range.

 Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not use the gas supply line for grounding

the appliance.

Failure to do any of the above could result in a
fire, personal injury or electrical shock.

Содержание 318201778

Страница 1: ...TRUCTIONS FOR FUTURE REFERENCE OBSERVE ALL GOVERNING CODES AND ORDINANCES Note For appliances installed in the state of Massachusetts see page 2 Refer to your serial plate for applicable agency certification NOTE 28 71 1 cm minimum clearance between the cooktop and the bottom of the cabinet when the bottom of wood or metal cabinet is protected by not less than 1 4 0 64 cm flame retardant millboard...

Страница 2: ...unattended Stepping leaning or sitting on the door of this range can result in serious injuries and can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminate the need to reach over the surface units cabinet storage space above the units should be avoided Adjust s...

Страница 3: ...ve or bypass the grounding prong Power supply cord with 3 prong grounding plug Figure 2 2 Electrical Requirements 120 volt 60 Hertz properly grounded dedicated circuit protected by a 15 amp circuit breaker or time delay fuse Note This range is not recommended to be installed with a Ground Fault Interrupt GFI Do not use an extension cord with this range Grounding Instructions IMPORTANT Please read ...

Страница 4: ...ak and possible fire or explosion The gas supply line to the shutoff valve should be 1 2 1 27 cm or 3 4 1 9 cm solid pipe The user must know the location of the main shutoff valve and have easy access to it When using flexible gas conduit on the range allow sufficient slack to pull the range outside the cutout for cleaning or servicing NOTE Do not allow the flexible conduit to get pinched between ...

Страница 5: ...er heated surface units cabinet storage space located above the range should be avoided If cabinet storage space is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinet Figure 5 Follow instructions for the type of installation you have Center Line of Range If range will be installed with a cabinet on bo...

Страница 6: ...normal operation after air has been purged from supply lines Visually check that burner has lit c Once the burner lights the control knob should be rotated out of the LITE position There are separate ignition devices for each burner Try each knob separately until all burner valves have been checked Regular Burner Burner Cap Fixed Burner Ring and Burner Base Dual Surface Burner Burner Base Fixed Bu...

Страница 7: ...igure 8 4 Adjust the LOW Setting of Regular Burner see figure 7 on the Surface Burner Valves Figure 8 a Push in and turn control to LITE until burner ignites b Quickly turn knob to LOWEST POSITION c If burner goes out reset control to OFF d Remove the surface burner control knob and decorative ring e Insert a thin bladed screwdriver into the hollow valve stem and engage the slotted screw inside Fl...

Страница 8: ...anti tip brackets are engaged Important Safety Warning To reduce the risk of tipping of the range the range must be secured to the floor by the properly installed anti tip bracket and screws packed with the range These parts are located in a plastic bag in the oven This gas range has two brackets Failure to install the bracket will allow the range to tip over if excessive weight is placed on an op...

Страница 9: ...la agencia de servicio o el proveedor de gas Nota Para electrodomésticos instalados en el estado de Massachussets Vea página 12 P N 318201778 0809 Rev A English pages 1 8 Español páginas 9 16 Notas páginas 17 19 Diagrama de la instalación alámbrica página 20 G F 13 Max 33 cm Max 35 7 8 Mín 91 1 cm Mín PARED PARED 18 Mín 45 7 cm Mín A B C D E NOTA Un espacio mínimo de 28 71 1 cm entre la superficie...

Страница 10: ...ard for Mobil Home Construction and Safety título 24 HUD parte 280 o cuando tal estándar no se aplica el Standard for Manufactured Home Installation 1982 Manufactured Home sites Communities and Setups ANSI Z225 1 NFPA 501A edición más reciente o con los códigos locales Esta estufa ha sido diseñada y certificada por el organismo CSA Internacional Como en cualquier electrodoméstico donde se use gas ...

Страница 11: ...ufe de pared con toma de tierra Figura 2 2 Requisitos eléctricos 120 voltio 60 Hertzio circuito dedicado apropiadamente puestos a tierra protegido por un circuito de amperio o fusible de demora de tiempo de 15 amp Nota no es recomendado instalarlo con un Interruptor GFI de puesta a tierra No utilice una extensión con esta estufa Instrucciones de puesta a tierra IMPORTANTE Por favor lea con cuidado...

Страница 12: ...onector codo de 90o Monte el conector flexible desde el tubo de suministro de gas hasta el conector T de gas según este orden 1 Válvula de cierre manual no incluido 2 Conector flexible no incluido 3 Conector codo de 90o no incluido 4 Conector T de gas incluido Conector T de gas Conexión del regulador El regulador esta instalado en el electrodoméstico Asegurese de no apretar demasiado la conexión E...

Страница 13: ...nter Line of Range Si la estufa se va a instalar con armarios laterales marque el centro de la abertura del armario en el piso ver la figura 5 Si la parte trasera de la estufa no estará a ras con la pared la ubicación del tomacorriente puede que no permita que la estufa se pegue a ras con la pared marque el piso donde estará el border trasero de la estufa Ponga el patrón en el piso alineando la lí...

Страница 14: ...sición LITE Cada quemador tiene su encendedor individual Controle las perillas separadamente hasta que todas las válvulas hayan sido controladas 4 Ajuste bajo LO para la válvula de los quemadores de superficie estandar Figuras 7 y 8 a Presione y gire el control hasta la posición LITE para prender los quemadores 6 Instalación de la estufa 1 La parte trasera de la estufa puede ser directamente insta...

Страница 15: ... a la POSICIÓN MÁS BAJA c Si el quemador se apaga reajuste el control a OFF d Retire la perilla del quemador de superficie Figura 9 e El tamaño de la flama de la porción posterior del quemador puente puede aumentarse o disminuirse dándole vuelta al tornillo A vea Figura 9 Utilice el tornillo B para ajustar el tamaño de la llama de la porción central del quemador puente o del quemador triple Dé vue...

Страница 16: ...este instalada utilice el diagrama en el cuadro 10 para situar el soporte si la plantilla no está disponible 4 Marque en el piso la localización de los agujeros de montaje demostrados en la plantilla posición derecha y izquierda Para una instalación más fácil los agujeros 1 2 1 3 centímetros de diámetro y 3 16 4 8 milímetros de profundidad pueden perforarse en el piso 5 Quite la plantilla y coloqu...

Страница 17: ...17 NOTES NOTAS ...

Страница 18: ...18 NOTES NOTAS ...

Страница 19: ...19 NOTES NOTAS ...

Страница 20: ...WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA 20 ...

Отзывы: