Adjusting the air flow (not valid for tumble dryers with heat pump)
Adjusting the air flow may only be carried out by authorized personnel.
Note!
For airflow adjustment ability, a damper need to be incorporated into the exhaust piping system.
It is important that the machine has the correct air volume compared to each machines effect. If the air flow is below
the minimum, the machine will be forced to switch the heating off which will result in longer drying time.
An air flow above needed is unnecessary and can result in a cold laundry room and noise from the piping and outlet.
In extreme causes this can result in longer drying time.
• Demount the rear panel.
2x
fig.X01344B
Insert the measuring instrument (manometer) in the hole (A). Make sure the connection is tight to prevent air leakage.
A
fig.X01750