Installation manual
19
Note!
The machine should be positioned so that there will be enough space for working, both for the user and
service personnel.
Respecting the given recommendations will provide easy access for maintenance and service operations.
In case of space limitations, it is possible to install machines without respecting to the given recommendations. If so,
keep in mind that it might be necessary to disconnect and move other machines to be able to reach and perform
service on affected machine.
4.5
Drain connection (only for machines with heat pump)
Connect a drain hose to the pipe (A) on the heat pump unit.
A
fig.X00695
Note!
The drain hose (A) must be positioned over the water level in the floor drain.
The drain must be lower than the drain outlet from the heat pump unit. If not the water will flow back into the
machine. Adjust with the feet.
The hose shall hang in a gentle arc.
4.6
Mechanical installation
Level the machine with the feet of the machine. The maximum height adjustment of the feet is 14 mm.
fig.W00177
Содержание Lagoon TD6-7
Страница 1: ...Installation manual Tumble dryer TD6 7 Lagoon Type N1 Original instructions 438905990 EN 2022 09 09 ...
Страница 2: ......
Страница 4: ......
Страница 44: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...