Installation manual
15
3.3.2
Technical data
Weight, net
kg
119
Drum volume
liters
135
Drum diameter
mm
575
Drum depth
mm
500
Drum speed, medium load
rpm
53
Rated capacity, filling factor 1:18 (Max. load)
kg
7.5
Rated capacity, filling factor 1:22 (Recommended load)
kg
6.1
Sound power/pressure level at drying*
dB(A)
63/48
Average heat emission per drying cycle used to assess ventilation need**
kW
0.7
Ambient operating temperature
℃
+10 – +45
* Sound power levels measured according to ISO 60704.
** For assistance with dimensioning necessary ventilation needs, contact authorized ventilation technician. For suffi-
cient ventilation all sources introducing heat need to be taken into account plus all other parameters effecting the
ventilation need. Climate zone, building parameters, room size, etc.
Connections
Pipe connection, condensed water
⌀
mm
15
Heat pump
Type of refrigerant
R134a
Amount of refrigerant
kg
0.68
Fluorinated greenhouse gases
This product contains fluorinated greenhouse gases:
R134a: 0.680 kg
GWP 1430
CO
2
equivalent 0.9724 t
Hermetically sealed