Congratulations!

 With buying a Electro-Voice CP-SERIES power amplifier you have chosen an appli-

ance that employs most advanced technology.
CP-Series power amps combine outstanding audio performance, highest reliability and operational 
safety. 

The audio performance of CP 1200 power amp is simply extraordinary. Optimised power supply units 
employing low-leakage toroidal transformers provide extensive headroom far above the stated nominal 
output. At the same time this contributes to a reduction in weight and power dissipation.
The CP 1200 is designed in Class-AB technology, have been designed to fulfil even the most demanding 
requirements  of  touring  applications.  The  CP  1200  amp  is  protected  against  thermal  and  electrical 
overload,  short  circuit  and  the  occurrence  of  HF/DC  at  the  outputs.  Back-EMF-Protection  eliminates 
the risk of the output transistors being damaged by electrical energy back-feed. The power outputs are 
switched via relay with a time delay during soft-start. An inrush current limiter prevents mains fuses from 
blowing.

Mechanical  construction  and  workmanship  also  comply  with  the  highest  precision  manufacturing 
standards. The rigid sheet steel chassis even resists the most wearing tour operation. Two three-speed 
high  performance  fans  (off/slow/fast)  guarantee  outstanding  thermal  stability  at  absolute  low  running 
noise. The ventilation is directed front-to-rear allowing trouble-free operation even in smaller amp-racks. 
The  electronically  balanced  inputs  are  carried  out  via  XLR-type  connectors  (female).  Direct-Outs  for 
through connecting the audio signal are also provided via XLR-type connectors (male). Input routing 
allows  selecting  DUAL  (stereo)  or  PARALLEL  (mono)  operation  mode.  By  means  of  the  separate 
BRIDGED OUT-connector and a Bridged Mode-switch, switching to „Mono Bridged”-operation is truly 
uncomplicated as well. 
The recessed mounted dB-scaled level controls ensure reliable protection against mechanical damage. 
These particularly precise, secure to operate detent-potentiometers are located on the front panel. 
The  easily  readable  LED  display  provides  a  quick  overview  of  the  power  amp’s  current  operational 
status. The power outputs CHANNEL A, CHANNEL B and BRIDGED OUT are carried out as extremely 
durable SPEAKON-type connectors. Also located on the rear panel is a Ground-lift switch, which helps 
eliminating ground-noise loops by separating the power amp’s enclosure from circuit ground. In normal 
operation, the CP 1200 power amp is capable of driving loads as low as 2ohms. In Mono-Bridged mode 
the allowable minimum load is 4ohms.
CP-Series  power  amps  provide  the  opportunity  for  retrofitting  an  internal  analogue  signal  processor 

board with x-over and filter functions.
This owner’s manual outlines and explains several other features of your CP 1200 power amplifier. 
Please, make sure to carefully read all of it and mind the instructions.

DESCRIPTION

Содержание Precision CP 1200

Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Страница 2: ...UT 8 SPECIFICATIONS TECHNISCHE DATEN 20 BLOCK DIAGRAM 21 DIMENSIONS ABMESSUNGEN 22 WICHTIGE SICHERHEITSHINWEISE 13 WICHTIGE SERVICEHINWEISE 13 BESCHREIBUNG 14 AUSPACKEN GARANTIE 15 INSTALLATIONSHINWEI...

Страница 3: ...cing other than that ontained in the Operating Instructions unless you are qualified to do so Refer all servicing to qualified service personnel 1 Security regulations as stated in the EN 60065 VDE 08...

Страница 4: ...se The ventilation is directed front to rear allowing trouble free operation even in smaller amp racks The electronically balanced inputs are carried out via XLR type connectors female Direct Outs for...

Страница 5: ...n easily rise up to 40 C during operation bearing in mind the maximally allowable environmental temperature during operation for all other appliances installed in the same rack shelf system is mandato...

Страница 6: ...iters This indicator lights as soon as the integrated dynamic audio signal limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity Short term...

Страница 7: ...y s audio appliances employ balanced outputs With balanced cabling the shield connects all metal enclosure parts and therefore efficiently eliminates the introduction of external interference mostly n...

Страница 8: ...handling such high voltages Please make sure that power handling specifications as stated in the docu mentation supplied with your speaker systems match the specifications of the power amplifier GROU...

Страница 9: ...nt per hour CP 1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3...

Страница 10: ...10...

Страница 11: ...BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Страница 12: ...SPACKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER 18 NETZEINGANG 18 NETZBETRIEB W RMEENTW...

Страница 13: ...t 11 Um das Ger t komplett spannungsfrei zu schalten muss der Netzstecker gezogen werden WICHTIGE SERVICEHINWEISE ACHTUNG Diese Servicehinweise sind ausschliesslich zur Verwendung durch qualifiziertes...

Страница 14: ...r niedrigem Ger uschpegel gew hrleistet Die Front to Rear Luftf hrung erlaubt den Betrieb auch in gro en und schmalen Endstufen Racks Die Eing nge sind elektronisch symmetrisch auf XLR Buchsen gef hrt...

Страница 15: ...temperatur der brigen im Gestellschrank befindlichen Ger te beachtet werden siehe auch Kapitel NETZBETRIEB UND W RMEENTWICKLUNG Achtung Die max Umgebungstemperatur von 40 C soll f r st rungsfreien Bet...

Страница 16: ...auf sobald einer der eingebauten dynamische Audio Limiter anspricht und die Endstufe ber der Aussteuerungsgrenze oder generell im Grenz bereich betrieben wird Kurzzeitiges Aufleuchten ist dabei unpro...

Страница 17: ...h aufgebaute Ausg nge Der Schirm im Kabel verbindet bei symmetrischer Signalf hrung alle metallischen Geh use und verhindert dadurch l cken los ein Einkoppeln von externen St rsignalen im wesentlichen...

Страница 18: ...ossenen Lautsprecher m ssen f r derart hohe Spannungen ausgelegt sein Beachten Sie unbedingt die Leistungsangaben im Datenblatt des jeweiligen Lautsprechers und vergleichen Sie diese mit der entsprech...

Страница 19: ...tunde CP1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3 Max Ou...

Страница 20: ...0Hz 7kHz 0 02 DIM30 3 15kHz 15kHz 0 01 Maximum Input Level 22dBu 9 76 Vrms Crosstalk ref 1kHz at rated output power 80dB Frequency Response ref 1kHz 15Hz 40kHz 1dB Input Impedance active balanced 20k...

Страница 21: ...21 BLOCK DIAGRAM...

Страница 22: ...22 ABMESSUNGEN...

Страница 23: ...23 NOTES...

Страница 24: ...nsville MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior n...