background image

2

3

The lightning flash with arrowhead symbol, within an 
equilateral triangle is intended to alert the user to the 
presence of uninsulated „dangerous voltage“ within 
the  product’s  enclosure  that  may  be  of  sufficient 
magnitude  to  constitute  a  risk  of  electric  shock  to 
persons

The exclamation point within an equilateral 
triangle is intended to alert the user to 
the presence of important operating and 
maintance (servicing) instructions in the 
literature accompanying the appliance.

1.  

Read these instructions.

2. 

Keep these instructions. 

3.  

Heed all warnings.

4. 

Follow all instructions.

5.  

Do not use this apparatus near water. Do not expose this apparatus to dripping or splahing and 

 

ensure that no objects filled with liquids, such as vases, are placed on this apparatus. 

6. 

Clean only with a dry cloth.

7.  

Do not block any of the ventilation openings. Install in accordance with the anufactures instructions.

8. 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus 

 

(including amplifiers) that produce heat.

9. 

Only use attachments/accessories specified by the manufacturer.

10.  

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 

 

damaged in any  way, such as power-supply cord or plug is damaged, liquid has been spilled or 

 

objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not

 

operate normally, or has been dropped

11. 

To completely disconnect mains power from this apparatus, the power supply cord must be 

 

unplugged.

CAUTION:  

These  servicing  instructions  are  for  use  by  qualified  personnel  only.  To  reduce 

   

 

the  risk  of  electric  shock,  do  not  perform  any  servicing  other  than  that  ontained 

  

 

in  the  Operating  Instructions  unless  you  are  qualified  to  do  so.  Refer  all  servicing 

  

 

to qualified service personnel.

1. 

Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to  

 

be obeyed when servicing the appliance

2. 

Use of a mains separator transformer is mandatory during maintenance while the appliance is  

 

 

opened, needs to be operated and is connected to the mains

3. 

Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4. 

The minimum distance between parts carrying mains voltage and any accessible metal piece (metal  

 

enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times.  

 

The minimum distance between parts carrying mains voltage and any switches or breakers that are not  

 

connected  to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.

5. 

Replacing special components that are marked in the circuit diagram using the security symbol (Note) is  

 

only rmissible when using original parts.

6. 

Altering the circuitry without prior consent or advice is not legitimate.

7. 

Any work security regulations that are applicable at the location where the appliance is being serviced  

 

have to be strictly obeyed. This applies also to any regulations about the work place itself.

8. 

All instructions concerning the handling of MOS - circuits have to be observed. 

SAFETY COMPONENT ( MUST BE REPLACED BY ORIGINAL PART )

NOTE:

IMPORTANT SAFETY INSTRUCTIONS

For US and CANADA only:

Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third 
grounding prong. The wide blade or the third prong are provided for your safety. When the provided plug does not 
fit into your outlet, consult an electrican for replacement of the absolete outlet.

IMPORTANT SERVICE INSTRUCTIONS

Содержание Precision CP 1200

Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Страница 2: ...UT 8 SPECIFICATIONS TECHNISCHE DATEN 20 BLOCK DIAGRAM 21 DIMENSIONS ABMESSUNGEN 22 WICHTIGE SICHERHEITSHINWEISE 13 WICHTIGE SERVICEHINWEISE 13 BESCHREIBUNG 14 AUSPACKEN GARANTIE 15 INSTALLATIONSHINWEI...

Страница 3: ...cing other than that ontained in the Operating Instructions unless you are qualified to do so Refer all servicing to qualified service personnel 1 Security regulations as stated in the EN 60065 VDE 08...

Страница 4: ...se The ventilation is directed front to rear allowing trouble free operation even in smaller amp racks The electronically balanced inputs are carried out via XLR type connectors female Direct Outs for...

Страница 5: ...n easily rise up to 40 C during operation bearing in mind the maximally allowable environmental temperature during operation for all other appliances installed in the same rack shelf system is mandato...

Страница 6: ...iters This indicator lights as soon as the integrated dynamic audio signal limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity Short term...

Страница 7: ...y s audio appliances employ balanced outputs With balanced cabling the shield connects all metal enclosure parts and therefore efficiently eliminates the introduction of external interference mostly n...

Страница 8: ...handling such high voltages Please make sure that power handling specifications as stated in the docu mentation supplied with your speaker systems match the specifications of the power amplifier GROU...

Страница 9: ...nt per hour CP 1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3...

Страница 10: ...10...

Страница 11: ...BEDIENUNGSANLEITUNG PRECISION SERIES CP 1200...

Страница 12: ...SPACKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER 18 NETZEINGANG 18 NETZBETRIEB W RMEENTW...

Страница 13: ...t 11 Um das Ger t komplett spannungsfrei zu schalten muss der Netzstecker gezogen werden WICHTIGE SERVICEHINWEISE ACHTUNG Diese Servicehinweise sind ausschliesslich zur Verwendung durch qualifiziertes...

Страница 14: ...r niedrigem Ger uschpegel gew hrleistet Die Front to Rear Luftf hrung erlaubt den Betrieb auch in gro en und schmalen Endstufen Racks Die Eing nge sind elektronisch symmetrisch auf XLR Buchsen gef hrt...

Страница 15: ...temperatur der brigen im Gestellschrank befindlichen Ger te beachtet werden siehe auch Kapitel NETZBETRIEB UND W RMEENTWICKLUNG Achtung Die max Umgebungstemperatur von 40 C soll f r st rungsfreien Bet...

Страница 16: ...auf sobald einer der eingebauten dynamische Audio Limiter anspricht und die Endstufe ber der Aussteuerungsgrenze oder generell im Grenz bereich betrieben wird Kurzzeitiges Aufleuchten ist dabei unpro...

Страница 17: ...h aufgebaute Ausg nge Der Schirm im Kabel verbindet bei symmetrischer Signalf hrung alle metallischen Geh use und verhindert dadurch l cken los ein Einkoppeln von externen St rsignalen im wesentlichen...

Страница 18: ...ossenen Lautsprecher m ssen f r derart hohe Spannungen ausgelegt sein Beachten Sie unbedingt die Leistungsangaben im Datenblatt des jeweiligen Lautsprechers und vergleichen Sie diese mit der entsprech...

Страница 19: ...tunde CP1200 Umains V Imains A Pmains W Pout W Pd 5 W BTU hr 1 idle 230V 0 37 42 42 143 Max Output Power 8 1 230V 4 6 743 2 x 240 263 895 Max Output Power 4 1 230V 7 5 1310 2 x 400 510 1740 1 3 Max Ou...

Страница 20: ...0Hz 7kHz 0 02 DIM30 3 15kHz 15kHz 0 01 Maximum Input Level 22dBu 9 76 Vrms Crosstalk ref 1kHz at rated output power 80dB Frequency Response ref 1kHz 15Hz 40kHz 1dB Input Impedance active balanced 20k...

Страница 21: ...21 BLOCK DIAGRAM...

Страница 22: ...22 ABMESSUNGEN...

Страница 23: ...23 NOTES...

Страница 24: ...nsville MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior n...

Отзывы: