CONTRACTOR PRECISION SERIES
36 Owner‘s Manual / Bedienungsanleitung
1) Sine Modulation (1 kHz)
2) Pink Noise EN60065 / 7. Edition
3) 1 BTU = 1055.06 J = 1055.06 Ws
4) P
d
= Power Dissipation
CPS8.5
Output
Mode
U
mains
in V
I
mains
in A
P
mains
in W
P
out
in W
P
d
in
W
4
BTU/hr
3
Idle
230
1.9
230
0
230
785
1/8 Max. Output Power @ 2
Ω
2
2
Ω
230
6.5
930
8x63
426
1454
1/8 Max. Output Power @ 4
Ω
2
4
Ω
230
6.0
860
8x63
356
1215
1/8 Max. Output Power @ 70 V / 100 V
2
70 V / 100 V
230
5.6
800
8x63
296
1010
1/3 Max. Output Power @ 2
Ω
2
2
Ω
230
8x167
1/3 Max. Output Power @ 4
Ω
2
4
Ω
230
8x167
1/3 Max. Output Power @ 70 V / 100 V
2
70 V / 100 V
230
8x167
Normal Mode (-10dB) @ 2
Ω
1
2
Ω
230
8x45
Normal Mode (-10dB) @ 4
Ω
1
4
Ω
230
8x45
Normal Mode (-10dB) @ 70 V / 100 V
1
70 V / 100 V
230
8x45
Alert (Alarm) Mode (-3dB) @ 2
Ω
1
2
Ω
230
8x225
Alert (Alarm) Mode (-3dB) @ 4
Ω
1
4
Ω
230
8x225
Alert (Alarm) Mode (-3dB) @ 70 V / 100 V
1
70 V / 100 V
230
8x225
preliminary