User Variable List
Var #
Description
Pg
#
Default
Value
User’s
Value
Var01
Encoder Type Select
0000 = 4-20mA Analog
0001 = Pulse Train
2
0000
Var02
PPR Value
2
0008
Var03
Pulse Max RPM or
RPM @ 20mA
2
0200
Var04
Speed Slowdown Alarm
SetPoint %
2
0090
Var05
Speed Slowdown Alarm
Delay
2
0001
Var06
Speed Shutdown Alarm
SetPoint %
2
0080
Var07
Speed Shutdown Alarm
Delay
2
0001
Var08
Underspeed Start Delay
Time
2
0005
Var09
Speed Display Select
0000 = % w/Alarms
0001 = RPM w/Alarms
0002 = % w/o Alarms
0003 = RPM w/o Alarms
3
0000
Var10
Max Analog RPM
3
0200
Var11
Belt Alignment Sensor Type
Select
(4-20mA or
Contact Closure)
0 = 4-20mA Sensor
1 = Contact Closure Sensor
xxx
?
= TRB (Inputs 11,12)
xx
?
x = KRB (Inputs 7,8)
x
?
xx = HRB (Inputs 3,4)
0xxx = Open Ckt = Good
1xxx = Closed Ckt = Good
3
0000
Var12
Temp Warning SetPoint
4
0160
Var13
Temp Shutdown
SetPoint
4
0175
Var14
Input #1 Bias Temp Set-
Point
4
0000
Var15
Input #2 Bias Temp Set-
Point
4
0000
Var16
Input #3 Bias Temp Set-
Point
4
0000
Var17
Input #4 Bias Temp Set-
Point
4
0000
Var18
Input #5 Bias Temp Set-
Point
4
0000
Free Catalog and Application Assistance
1.800.328.6170
Website: www.electro-sensors.com
990-005500 Revision D
21
Var19
Input #6 Bias Temp Set-
Point
4
0000
Var20
Input #7 Bias Temp Set-
Point
4
0000
Var21
Input #8 Bias Temp Set-
Point
4
0000
Var22
Input #9 Bias Temp Set-
Point
4
0000
Var23
Input #10 Bias Temp Set-
Point
4
0000
Var24
Input #11 Bias Temp Set-
Point
4
0000
Var25
Input #12 Bias Temp Set-
Point
4
0000
Var26
Unused
N/A
Var27
Unused
N/A
Var28
Unused
N/A
Var29
Unused
N/A
Var30
Temp Display Select
0000 = ºF
0001 = ºC
4
0000
Var31
Hour Meter Warning Time
(In hours)
4
9000
Var32
Hour Meter Maint. Time
(In hours)
5
9500
Var33
Horn Operation Select
0xxx = Solid Horn
1xxx = Oscillating Horn
x000 - x999 = Horn ‘time’
in Minutes.
5
0999
Var34
Hour and Speed Command
Select.
0000 = Maintained
Disable/Enable.
0001 = One-Shot
Disable/Enable
w/Disable = Closed.
0002 = One-Shot
Disable/Enable
w/Disable = Open.
6
0000
Var35
Test Mode Select
0000 = Operate
0001 = Test w/Relays
0002 = Test w/o Relays
0003 = Test w/o Relays
0004 = Test w/Manual
Relay control
6
0000
Var36
Software Identification
(Read Only)
7
N/A