temperature displays. See Troubleshooting Section,
“Out-of-range Sensor Detection” for details.
2) Electro-Sentry 1’s 4-digit LED speed display can show in
‘%’ or in ‘RPM’, as per the
Var09
selection (as already
discussed). However to aid in troubleshooting , the small
LCD display (mainly used for UserVar programming)
can toggle between % and RPM just by pressing the
INCREMENT button when in Normal Mode. This LCD
feature is independent of
Var09
.
When displaying ‘%’ values the LCD shows the ‘OUT%’
icon in the upper-right-corner.
When displaying ‘RPM’ values the LCD does not show the
‘OUT%’ icon in the upper-right-corner.
Concerning the Var34 Disable/Enable Commands:
If an Hour_and_Speed_Enable command is NOT present
at
TB34
, then none of the Speed display’s discrete Green/
Yellow/Red LEDs are enabled, nor are the speed alarms
enabled. However even without an Hour_and_Speed_Enable
command present, the Speed display continues to show
speed in % or RPM - this is so speed can be displayed on a
ramp-down to ‘STOP’ after an Hour_and_Speed_Disable
command has been given.
If an Hour_and_Speed_Enable command is present at
TB34
AND
if
Var09
has Speed Monitoring Enabled, then the
Speed display’s discrete Green/Yellow/Red LEDs and speed
alarms are all enabled and will activate as needed.
Note:
Var09
can be used to disable Speed Alarm
Monitoring, thereby allowing the Hour_and_Speed_
Enable command to be used for starting/stopping just
the Hour_Meter in those applications that do not use
Speed Alarm Monitoring. See
Var09
for details.
Note: If an Hour_and_Speed_Enable command is already
present when changing
Var09
‘on-the-fly’, then the
effects of enabling Speed Alarm Monitoring are not
seen until after the
Var08
Underspeed Start Delay
time plus the time of
Var05
delay or
Var07
delay has
passed, after the instant
Var09
has been changed to
Enable Speed Alarm Monitoring.
Temperature sensors and their discrete LEDs, displays, and
alarms are always active, independent of the
Var34
based
Hour_and_Speed_Disable/Enable commands.