![Electro-Sensors Electry-Sentry 1 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/electro-sensors/electry-sentry-1/electry-sentry-1_installation-and-operation-manual_2379885026.webp)
AC Power Inputs
115Vac/
230Vac
TB29
1
Hot (115Vac)
2
Earth Ground
3
Neutral
(Hot 230Vac)
Frequency Pulse Train Speed Input
Pulse-Train
Input
TB30
1
+24 Vout Digital
(Resettable fused at
27mA max, at
70ºC/158ºF)
2
Signal
3
Digital Ground
Remote Switch Digital Inputs (Contact Closure)
Aux Hour
Meter Reset
TB31
1
Input
2
Digital Ground
Aux Test Left Side
Temp Rise
3
Input
4
Digital Ground
Aux Test Right Side
Temp Rise
5
Input
6
Digital Ground
Aux Test Speed Drop
7
Input
8
Digital Ground
Aux Silence Horn
/Alarm Reset
9
Input
10
Digital Ground
Hour_and_Speed_
Disable command
TB32
1
Input
2
Digital Ground
Silence Horn/Alarm
Reset
TB33
1
Input
2
Digital Ground
Hour_and_Speed_
Enable command
TB34
1
Input
2
Digital Ground
*Note: Analog input “pairs” and their corresponding terminal
blocks are described on Page 15.
Example: Two sensors per pair with each drawing 25mA each is
permissable. One sensor drawing 50mA is permissable as long as
no sensor is used in its corresponding “paired” input.
SW1 Vac Selection Switch
The Vac power is selectable via selector switch SW1 located next
to the Vac TB29 terminal block on the I/O terminal board. Slide
the switch to the right for 115 Vac or to the left for 230 Vac.
The ES1 is shipped with SW1 set for 115Vac, and with the
replaceable fuse, F12, as a 115Vac/0.4Amp Slo-Blo fuse.
If your application needs SW1 switched to 230Vac, then also
install a 230Vac/0.2Amp Slo-Blo fuse into F12
The ES1 is shipped with one extra 115Vac/0.4Amp Slo-Blo fuse
and one 230Vac/0.2Amp Slo-Blo fuse.
Free Catalog and Application Assistance
1.800.328.6170
Website: www.electro-sensors.com
990-005500 Revision D
18
Terminal Block Connections
Analog Inputs (4-20mA)
Analog Inputs 1 - 16
(TB13, 14, 15
Unused)
TB1
Through
TB16
1
+24 Vout Analog
(Resettable fused at
50mA per pair max,
at 70ºC/158ºF)
See* note below
2
4-20mA Signal
3
Analog Ground
Relay Outputs (Dual Form C SPDT)
Relay #1
Speed Only
Warning
TB17
1
Normally Open
2
Common
3
Normally Closed
TB18
1
Normally Open
2
Common
3
Normally Closed
Relay #2
Speed Only
Shutdown
TB19
1
Normally Open
2
Common
3
Normally Closed
TB20
1
Normally Open
2
Common
3
Normally Closed
Relay #3
Speed/Temp
Warning
TB21
1
Normally Open
2
Common
3
Normally Closed
TB22
1
Normally Open
2
Common
3
Normally Closed
Relay #4
Speed/Temp
Shutdown
TB23
1
Normally Open
2
Common
3
Normally Closed
TB24
1
Normally Open
2
Common
3
Normally Closed
Relay Outputs (Single Form A SPST)
Relay #5
Green Light (Stack)
TB25
1
Normally Open
2
Common
Relay #6
Yellow Light (Stack)
TB26
1
Normally Open
2
Common
Relay #7
Red Light (Stack)
TB27
1
Normally Open
2
Common
Relay #8
Horn
TB28
1
Normally Open
2
Common
Содержание Electry-Sentry 1