05/21/2009 3
BI501
zone and the installer selects one of four zone capacity sizes. When dialing in the size closest to the zone
Btu/h capacity, the zone controller “smarts” only allows the appropriate boiler stage which can handle that
capacity. Also this is additive if more than one zone calls at any one time – order EB-ZTS-1.
3.
Two temperature system with unbalanced zones
– if the application includes zone one requiring high
temperature (fin tube, air handler, etc.) and the remaining zones are radiant floor low temperature, this zone
controller (EB-ZTS-1) will automatically raise the output of the high temperature zone. This is a priority
arrangement, zone 1 holds off the other zones while the high temperature output is heating. If at the end of
the high temperature zone there is a call on any of the low temperature zones (up to three plus slave 4),
there will be a pump only function until the outlet temperature drops below the front panel dial setting.
Field zone controller installation
– the above mentioned zone controller board is installed within the
basic cabinet.
However
, the zone controller board must communicate with the main TS boiler board. All
production units after approximately January 10, 2004 have a compatible control board. If the zone
controller installation is in a boiler manufactured prior to that date, call factory to review the requirements
for a main controller board upgrade.
ZONE CIRCULATORS
The EE-5051 switching relay can be used to interface line voltage pumps with the boiler R and W control
terminals, see drawing BH008. This switching relay can be combined with the above zone controller
board.
ROOM THERMOSTAT PLACEMENT
Fin tube radiation, fan coil, etc. –
heat only wall t-stat, connected to operate zone valves (see previous
section) or for single zone the t-stat is connected directly to Electro-Boiler R and W.
Floor radiant
– comfort and proper space heating response is a direct relationship to the thermostat type
and the placement of the thermostat sensing bulb. Typically an under floor heating system can be broken
down into three categories.
A.
Energy storage, water tubing is under the concrete or within the sand base
– the controlling thermostat must have a remote bulb, and this remote bulb must
sense the concrete slab temperature (slab stat). Coordinated with the concrete
pour, install a ¾” PVC, minimum bend radius of 7 inches, and locate at
approximately center (vertical) of the concrete slab. The thermostat sensing
bulb can later be pushed down this PVC conduit. If the slab is already poured
without conduit for slab stat, use electronic remote sensing thermostat such as
Electro Industries’
ES-24-SRO or ES-24-C-RS
. These devices only require a
¼” hole drilled in the floor at some convenient location (preferably off a center
wall, not within 2 feet of outside wall).
B.
Floor covering, medium to high insulation
– use slab stat as described in paragraph A above.
C.
Quick response, hydronic tubing just under the concrete surface, no flooring material over the
concrete
– in this case, heated water can directly radiate into the room, a standard wall mount room
thermostat is adequate. Mount room thermostat on an inside wall similar to most heating systems.
MULTIPLE BOILERS
This boiler series now includes a method for automatically staging
any number of parallel-plumbed boilers. Order plug-in relay EB-C-
STG5.
The thermostat is connected only to the first boiler, when all stages
are on for more than 5 minutes, this new plug-in relay module turns
on the next boiler (R and W), and a second EB-C-STG5 could be
used to turn on the third, etc.