ELECTRO FREEZE Soft Serve Model 99T-RMT
12 Troubleshooting Table
(continued)
1.
Plunger switch rod engaged.
1. Close plunger completely.
2.
Plunger not seated in head.
2. Push plunger down.
3.
Plunger switch (side or center) out of
adjustment or defective.
3. Contact your Electro Freeze Distributor
for service.
4.
Faulty thermostat or bulb not deep
enough in well.
4. Contact your Electro Freeze Distributor
for service.
5.
Starter or relay contact points stuck.
5. Contact your Electro Freeze Distributor
for service.
6.
Faulty time delay.
6. Contact your Electro Freeze Distributor
for service.
7.
Suction pressure too low.
7. Contact your Electro Freeze Distributor
for service.
Freezer runs
continually and
product
continues to get
colder.
8.
Mechanical timer stuck or faulty.
8. Contact your Electro Freeze Distributor
for service.
1.
Worn scraper blade.
1.
Replace scraper blade.
2.
Dirty or blocked condenser, restricted
air or water flow – high ambient
temperature.
2.
Have condenser cleaned by your
Electro Freeze Distributor; lower
ambient temperature.
3.
Thermostat cut-in point out of
adjustment or malfunctioning.
3.
Contact your Electro Freeze Distributor
for service.
4.
Defective condenser fan motor.
4.
Contact your Electro Freeze Distributor
for service.
Poor or slow
product
recovery.
5.
Component or compressor failure.
5.
Contact your Electro Freeze Distributor
for service.
PROBLEM
PROBABLE CAUSE
REMEDY