ELECTRO FREEZE Soft Serve Model 99T-RMT
184621
39
11 Routine Maintenance
(continued)
MONTHLY (
continued)
C. MTS Cover Switch
(continued
)
4. Look at the MTS rollers; they should
NOT
be rotating. If they are rotating, turn
"OFF" mix switch and discontinue use until
repairs can be made.
5. If there is no movement, slowly install
cover and listen for the gear motor to turn on.
The cover should be almost completely
closed when the gear motor turns on.
DO NOT
insert fingers or objects into roller
cavity during this test. If the MTS does not
operate as described here, or you are unable
to determine if the MTS is operating properly,
turn the switches to the “OFF” position,
disconnect the main power supply and
contact your Electro Freeze Distributor for
service.
DO NOT
place the freezer in service
until the problem has been corrected.
D. Replace the Mix Transfer
Hose
CAUTION
Make sure the freezer is
depressurized before
proceeding.
CAUTION
To avoid electrical shock or
contact with moving parts, make
sure all switches are in the
“OFF” position and that the main
power supply is disconnected.
Some freezers have more than
one disconnect switch.
QUARTERLY
A.
Air Condenser.
Important:
Never use a screwdriver or sharp
object to clean between fins.
On air cooled freezers have the air
condenser fins cleaned by your Electro
Freeze Distributor to remove dirt,, lint
and dust.
B.
Refrigeration System
Have your Electro Freeze Distributor
check the refrigeration system and make
any necessary adjustments.