ELECTRO FREEZE Soft Serve Model 99T-RMT
12
184621
5
Operator Controls and Indicators
CAUTION
Test operation of the head
switch prior to placing the
freezer in service. See Section
11, Routine Maintenance,
Monthly.
This three-position switch controls the
operating mode of your freezer.
a. "
CLEAN"
(left) — This position
operates the beater only (no refrigera-
tion to the cylinder). This position must
be used in all cleaning and sanitizing
operations.
b.
"OFF"
(center) — In this posi-
tion the beater motor and refrigeration
system will not operate.
Important:
Do not use the "AUTO" position with
water or sanitizer in the cylinder —
the freezer will be damaged.
c.
"AUTO"
(right) — This position
activates both the beater motor and the
refrigeration unit. This is the normal
operating position.
5.1 Selector Switch 1
The following paragraphs describe the
operator controls and indicators. Refer to
figure 5-1 for location of these controls
and indicators on the freezer.
NOTE
: The head must be in place before
the beater will operate.
Figure 5-1