2-2
Installation
P/N 0013-1025-001 Rev F
* Indicates Factory Setting
P8
2-3
External Opto Power
Customer supplies power (24V) to opto’s on
FAC, RAC and INHibit inputs.
P8A
2-3
External Sourcing Opto’s
Opto’s are sourcing inputs (pulled up to 24V
by external power when true).
NOTE
: External power polarity connec-
tions define circuit as sourcing.
P8A
2-3
External Sinking Opto’s
Opto’s are sinking inputs (pulled down to
0V by external power when true).
NOTE
: External power polarity connec-
tions define circuit as sinking.
P9 & P9A
1-2
SSO Relay
System Status Output is controlled by a
relay
2-3
∗
SSO Open Collector
System Status Output is controlled by an
open collector transistor
Intro
F
IGURE
2.1
Jumper Locations
T
ABLE
2.1
Inputs and Outputs with Jumpers P6 through P9A (continued)
Jumper
Pins
Position
Operation
Page
NOTE
: Figure depicts factory jumper settings. Refer to the “Internal Connections (FAC, RAC
and INH)” on page 2-11 for diagrams to connect externally powered opto’s.
1 2 3
VERR
EN INTG
+15V -15V
C22
C21
P2
P1
ICMD
VCS
TACH
COMP
BAL
ILIM
P6
P7
P8 P8A
P9 P9A
P7
2-3 = RAC DISABLE
1 2 3
P6
2-3 = FAC DISABLE
3
2
1
P8A
1-2 = SOURCING OPTO’S
1
2
3
P9A
1
2
3
P9
3
2
1
P8
1-2 = INTERNAL OPTO POWER
2-3 =
SSO OPEN
COLLECTOR
OUTPUT
Содержание MAX-430
Страница 33: ...Applying Power for the First Time 3 5 Instruction Manual Intro FIGURE 3 1 System Response to a Step VCS Input ...
Страница 36: ...3 8 Applying Power for the First Time P N 0013 1025 001 Rev F ...
Страница 42: ...4 6 Diagnostics Troubleshooting P N 0013 1025 001 Rev F ...
Страница 50: ...6 6 Component Ordering Information P N 0013 1025 001 Rev F ...
Страница 52: ...7 2 Reference Drawings P N 0013 1025 001 Rev F Intro FIGURE 7 2 Simplified Circuit Diagram ...
Страница 54: ...A 2 Differences from the MAX 400 P N 0013 1025 001 Rev F ...
Страница 58: ...Help 4 Documentation Improvement Form P N 0013 1025 001 Rev F Second Fold Tape First Fold ...