3-11 Programming
Input ANDing
Menu Path
MAIN SCREEN
to CONFIG MENU
to CHN ANDING MENU
to INPUT ANDING
Background
Terminals 1 through 8 of TB 3, Figure 7, can accept hardware input signals from sen-
sors or PLC’s. By ANDing an output channel with one of these terminals, the output
channel will be “on” only when a signal is present on that terminal AND the setpoints
programmed for that output channel are “on.”
Programming
Use the INC and DEC keys, or the numeric keypad and ENT to select an output chan-
nel.
Use the SEL key to select input terminals 1 through 8, or to turn Channel ANDing “off”
for that output channel. IN1 = Input Terminal 1, IN2 = Input Terminal 2, and so on.
Operation
• Any number of output channels can be ANDed to a single input terminal.
• Input ANDing, Shift Register ANDing, and Motion ANDing can be combined for any
given output channel.
• When Input ANDing is activated for a channel, it will apply to that channel in all pro-
grams.
Input Status
Menu Path
MAIN SCREEN
to SETUP MENU
to I/O STATUS
to INPUT STATUS
The input status screen displays the On/Off status of the DC inputs on Terminal Blocks
TB 9 and TB 11, Figure 7.
Inputs are numbered 1 through 16, but only 8 inputs are shown at one time. The On/Off
status is shown under the input number; 0=Off, 1=On.
Selecting Inputs
You may view inputs 1-8 or 9-16. Press the SEL key to toggle between the two groups
of inputs.
12345678 INPUT
01001001 1-8<
Input Numbers (1-8)
Input On/Off Status (0=Off, 1=On)
90123456 INPUT
01001001 9-16<
Input Numbers (9-16)
CHN: 1
INPUT AND:IN1
Output Channel
Input Terminal (1-8, or OFF)