3-10 Programming
Increasing Direction
Menu Path
MAIN SCREEN
to CONFIG MENU
HARDWARE
to INCREASING DIR
Purpose
The Increasing Direction screen displays the direction of encoder rotation (CW or CCW
as viewed from the shaft end) that will cause the position display to increase in value.
This is normally set so the position value increases as the machine turns in its forward
direction.
Changing Direction
Press SEL to toggle the value of increasing direction. The new value will begin flashing.
Press the ENT key to confirm your selection.
Enable Options
Menu Path
MAIN SCREEN
to CONFIG MENU
to PGM ENABLE MENU
to ENABLE OPTIONS
Purpose
The Enable Options screen controls Operator Level access to SETUP MENU program-
ming as indicated in Figure 21, note 1.
This screen lists the various items in the SETUP MENU, and allows you to turn Opera-
tor access to those items on or off.
Access to the “on” items will be available only for those output channels that
have been turned ON in PER CHN ENABLE.
Programming
Press the Up Cursor and Down Cursor keys to select the function you wish to change.
Press the SEL key to turn Operator access ON or OFF.
Setup Menu Items
Access can be turned on or off for the following SETUP MENU items:
SETPOINTS
DEFAULT PROGRAM
SPEED COMP
OFFSET
MOTION DETECT
ANALOG OUTPUTS
SHIFT POSITION
See Also
PER CHN ENABLE
SETPOINTS<
ENABLE: ON
SETPOINTS or SETUP MENU screen.
Scroll through choices with UP and Down cursor keys.
OPERATOR ENABLE: ON/OFF
(Toggle with SEL key)
INCREASING
DIR: CCW<
Direction of resolver shaft rotation (viewed from
shaft end) that will cause the postion display to
increase in value.