Using the power supply
Sounds
Key sound
Default:
YES
= YES
A short beep signalises a key press
= NO
No signal if keys are pressed
Alarm sound
Default:
YES
= YES
If an alarm or warning occurs an acoustic
signal is emitted (beep) in short intervals
= NO
No acoustic signal for alarms/warnings
Displaying the cooler temperature
You can enable the cooler temperature to be displayed which
can be used to monitor a certain thermal stability inside the
unit. At temperatures above 80°C ±3°C the unit will shut down
the power output.
Cooler temp.
Default:
NO
= YES
Temperature is displayed in °C
= NO
No temperature displayed
7.5 Configuring the graphic display
D
The menu page
Display
lets you configure all parameters
related to the graphic display.
Backlight
Default:
YES
= YES
The backlight is permanently on
= NO
The backlight is permanently off
= delay 60s
The backlight will be switched off with a
delay of 60s after a key or a rotary knob
has been used the last time
Contrast
Default:
80%
= { 70%...90% }
The contrast can be adjusted to suit the needs of the location
where the unit is installed and for a clearer view at the values.
7.6 Supervision
Super
The
Supervision
menu lets you configure the supervision
of output voltage, output current and output power. You can
also supervise a step function. The menu
Supervision
leads you to following menu selection:
Alarm manager
U thresholds
I thresholds
Step response
7.6.1
Alarm management
Alarm m
The menu page
Alarm manager
lets you configure how
the power supply shall „react“ in case of an error. You can
specify different reactions to various supervision items and
errors.
Supervise U<
Default:
NO
= NO
No supervision of undervoltage
= Signal
Undervoltage is notified as a signal
= Warning
Undervoltage is notified as a warning
= Alarm
Undervoltage is notified as an alarm
Supervise U>
Default:
NO
= NO
No supervision of overvoltage
= Signal
Overvoltage is notified as a signal
= Warning
Overvoltage is notified as a warning
= Alarm
Overvoltage is notified as an alarm
Supervise I<
Default:
NO
= NO
No supervision of undercurrent
= Signal
Undercurrent is notified as a signal
= Warning
Undercurrent is notified as a warning
= Alarm
Undercurrent is notified as an alarm
Supervise I>
Default:
NO
= NO
No supervision of overcurrent
= Signal
Overcurrent is notified as a signal
= Warning
Overcurrent is notified as a warning
= Alarm
Overcurrent is notified as an alarm
Supervise step
Default:
NO
Us
→
Uo
Supervision of a voltage step
Is
→
Io
Supervision of a current step
Ps
→
Po
Supervision of a power step
= NO
No supervision of steps
= Signal
Supervision errors are notified as a signal
= Warning
Supervision errors are notified as a warning
= Alarm
Supervision errors are notified as an alarm
The parameters which will define the reaction of the power
supply, after the supervised step has occured (step response),
are configured in
Step response
.