49
© 2006, Elektro-Automatik GmbH & Co. KG
EN
Using the power supply
7. Device configuration
Part 1: The menu
Profile
This is an overview of the parameter pages, starting from
the menu
Profile
. The red colored menu is only displayed
if the option „internal resistance“ is unlocked.
Menue
Profile
Setup operation mode
Control panel
General settings
Load profile from
user profile = default|[1,2,3,4]
[ R adj min = 0.000
Ω ]
U adj= 0.0 V 300.00 V
Key sound = NO | YES
Backlight =delay 60 s | NO | YES
Alarm sound =NO | YES
P adj max= 0.100kW
Key lock =enable |disable | except OFF
OT alarm disappears = OFF | auto ON
Load profile
Save profile
Save profile to
user profile=
1|[2,3,4]
Operation mode = U/I/P | U/I/R
Power ON = OFF | restore
I adj= 0.0 A 300.00 A
I
<
= 0.0 A T
I<
=0.100s
I
>
= 300.0 A T
I>
=0.100s
No.
U[V]
I[A]
P[kW]
1
10.00
10.00
1.000
2
10.00
12.00
1.200
-
12.00
40.00
1.000
4
15.00
50.00
1.500
Preset list
Step response
Supervise step = Us
J
Uo|[Is
J
Io,Ps
J
Po]
fall time t sf = 0.100s [0.03s...60s]
rise time tsr = 0.100 s [0.03s...60s]
Supervision
Adjust limits
Accept set values
= direct | [ return key| from preset list ]
U ovp= 310.00 V
U
<
= 0.0 V T
u<
=0.100s
U
>
= 300.0 V T
u>
=0.100s
U thresholds
I thresholds
Step response
Alarm manager
Supervise
U< = xx U>= xx
I< =xx I> = xx
(xx = NO|[ Signal | Warning | Alarm])
Supervise step
Us
J
Uo |[Is
J
Io,Ps
J
Po] = xx
(xx = NO|[ Signal | Warning | Alarm])
dyn.
∆
U [
∆
I|
∆
P]= 10.00V
Cooler temp. = NO | YES
Display
Contrast = 80%
M
+
The profiles are intended to minimize to time needed to set
up the device at alternating users or to keep user defined
settings for repeating applications. The last used profile is
always loaded after the unit is switched on.
The menu entry
Profile
leads you to following selection:
General settings
Supervision
Load profile
Save profile
General se
The menu entry
General settings
leads to following
selection where the operation mode, the display itself and
the handling (adjustment) of the unit can be configured:
Setup operation mode
Preset list
Adjust limits
Control panel
Display
Super
The menu entry
Supervision
leads to following selection
where alarms, warnings and signals, as well as the
corresponding supervision limits and reaction times are set
up.
Alarm manager
U thresholds
I thresholds
Step response
Load p
Load profile from user profile = {default, 1..4}
The current profil is replaced by the selected one.
Save p
Save profile to user profile = {1..4}
The current profile can be stored into one out of four profiles.