background image

 

Electroair Acquisition Corp. 

IM EA-15000 

Page 9 of 10 

Revision 01 

Prepared by:  EAC 

02/04/2020 

 

 

Figure 5: Configuration A and B Back Surfaces 

 

4.  Final Installation Steps: 

 

 

CAUTION: If using a non-impulse coupled magneto aka direct 
drive magneto aka non-starting magneto, update pilot checklist/ 
POH to have MAG switch in OFF position during starting.

 

 

  Start the aircraft per the AFMS and perform a ground run-up. 

o

  Check for proper starter function. 

o

  Check for proper RPM drop on Left Magneto. 

o

  Check for proper RPM drop on Right Magneto. 

  If the aircraft passes, then return to service. 

  If the aircraft fails, then verify that all of the connections are correct and 

competent and that no other wires were damaged during the install.  Repeat the 
start-up process. 

  If the aircraft fails a second time, contact the factory for support.  (248-674-3433 

or 

[email protected]

Содержание EA-15000

Страница 1: ...evision 01 Prepared by EAC 02 04 2020 Electroair Acquisition Corp 5097 Williams Lake Road Waterford MI 48329 U S A Phone 248 674 3433 Fax 248 674 4231 Email sales electroair net EA 15000 Installation...

Страница 2: ...STATEMENTS 5 INSTALLATION OF EA 15000 6 GLOSSARY AND ABBREVIATIONS 10 Table of Figures Figure 1 Configuration A Overall Dimensions 6 Figure 2 Configuration B Overall Dimensions 6 Figure 3 Configurati...

Страница 3: ...nds reading through this entire installation procedure before installing the Electroair Ignition Starter Switch Panel to your aircraft Make sure that any questions are answered before the actual insta...

Страница 4: ...TO OBTAIN THE STC AUTHORIZATION LETTER Receiving and Acceptance Checking of EA 15000 Kit 1 Inspect the packaging for damage before acceptance from the freight carrier If damaged refuse the package 2...

Страница 5: ...and either a poor performing EIS or the possibility of damaging equipment Prior to turning on bus power verify the wiring Please call Electroair with any questions sales electroair net or 248 674 3433...

Страница 6: ...ations Determine the proper location for the panel Determine the most appropriate mounting method Overall dimensions are provided in Figure 1 and Figure 2 Cutout dimensions are provided in Figure 3 an...

Страница 7: ...ry key switch location plug the hole left by removing the rotary key switch as necessary 3 Set up Installation of p n EA 15000 Ignition Starter Switch Panel Review the leads corresponding to the locat...

Страница 8: ...ectrical connectors are tight on switch connections Ensure wires will not pull out of any electrical connections Left Mag Switch o Connect ground to GND o Connect the P Lead from the Left Magneto to P...

Страница 9: ...during starting Start the aircraft per the AFMS and perform a ground run up o Check for proper starter function o Check for proper RPM drop on Left Magneto o Check for proper RPM drop on Right Magneto...

Страница 10: ...r Wheel EIS Electronic Ignition System FAA Federal Aviation Administration Ignition Timing is the process of setting the angle relative to piston position and crankshaft angular velocity that a spark...

Отзывы: