background image

•  Read all the instructions before 

installing, operating, maintaining, 

or using this product.

•  Supervise children when device is 

in use. Children under 16 should 

not operate this device.

•  Do not put fingers into the electric 

vehicle connector.

•  Do not use this product if the power 

cord or the electric vehicle cable 

 is frayed, has broken insulation, or 

any other signs of damage.

•  Do not use this product if the  

enclosure or the electric vehicle 

connector is broken, cracked, 

open, or shows any other indication 

of damage.

•  The maximum ambient temperature 

rating for this device is +122 °F (+50 °C).

•  Use only copper wire rated minimum 

194 °F (90 °C), maximum 7 AWG for 

connecting to main power supply.

•  Do not use extension cord to  

increase the length of the charging 

cable.

•  Installation must be performed 

only by a qualified, specialized 

electrician. Dock must be inspected 

by a qualified electrician prior to 

initial use.

•  Follow all federal, provincial and 

local laws, regulations, ordinances, 

building codes and safety standards 

when installing or using this device.

•  If an applicable law, regulation, 

ordinance, building code or safety 

standard would not permit you to 

complete a step as described in 

these Dock Installation Instructions, 

contact Electrify America Customer 

Assistance at 1-833-532-2778.

•  Electrify America is not responsible 

for physical injury, damage to  

property or equipment caused by 

the installation of this product.

•  This document provides instructions 

for the Dock and must not be 

used for any other product. Before 

installation or use of this product, 

the user must read and review this 

manual carefully and consult with 

a licensed contractor, licensed  

electrician, or trained installation 

expert to make sure of compliance 

with local and national building 

codes and safety standards, climate 

conditions, and all applicable codes 

and ordinances.

•  These Dock Installation Instructions 

describe the most commonly used 

installation and mounting scenarios. 

If it is not possible to perform an 

installation following the procedures 

provided in this document, contact 

Electrify America. Electrify America 

is not responsible for any damages 

that may occur from custom 

installations that are not described 

in these Dock Installation Instructions. 

•  Personal protection equipment: 

Use proper personal protection 

equipment, including, but not limited 

to eye protection, shock protection, 

gloves, and other appropriate 

protection when installing or 

servicing any electrical equipment.

•  Arcing component in contactor: 

The Dock includes contactors that, 

when opened or closed, will cause 

a short duration arc. The contactor 

is enclosed in an appropriate  

electrical enclosure, but caution is 

required if this arc occurs in the 

presence of flammable vapors, as 

the vapors could ignite, creating an 

explosion. 

Store hazardous 

and flammable vapors and 

materials away from all electrical 

equipment. If hazardous or 

flammable sources are present, 

allow sufficient time for 

ventilation before operating 

the Dock.

Do not open the charger at any 

time during installation or 

operation! Only trained personnel 

should open the Dock.

Product subject to modification 

without prior notice. This 

document might not contain 

the latest changes to the 

product's specifications or 

processes described herein. 

Visit www.electrifyamerica.com/

charging-at-home for the most 

up to date information.

CAUTION

To reduce the risk of fire, 

connect only to a circuit provided 

with 1 x 40 A maximum branch 

circuit overcurrent protection 

in accordance with the National 

Electrical Code and local  

standards regulations and codes.

CAUTION

Ensure that all components are 

dry throughout the installation. 

5

IMPORTANT SAFETY INSTRUCTIONS

DANGER

Handling live electrical 

components.incorrectly 

may cause grievous injuries 

or death.

DANGER

Choking hazard. Small parts are 

dangerous for children. Do not 

install in the presence of children.

WARNING

If the electricity service to the 

Dock or charger is damaged, 

immediately shut down the 

power to the Dock / charger 

by switching off the circuit 

breaker and contact a licensed 

electrician. 

WARNING

The product must not be 

installed in ex-zones (potentially 

explosive atmospheres)

Содержание innogy eBox professional

Страница 1: ...Dock installation instructions...

Страница 2: ...2 DOCK INSTALLATION INSTRUCTIONS...

Страница 3: ...he site 12 Routing the connecting cable 12 Line selection 12 Tools needed 13 Information on mounting 14 Mounting the Dock on a wall 14 Preparing the electrical connection 16 Ethernet link optional 16...

Страница 4: ...rovide these Dock installation Instructions to any future owner of the charger Note For your safety these devices must be stored installed used serviced and ifnecessary dismounted and disposed of prop...

Страница 5: ...orm an installation following the procedures provided in this document contact Electrify America Electrify America is not responsible for any damages that may occur from custom installations that are...

Страница 6: ...ference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the u...

Страница 7: ...I Do not provide external GFCI on the supply power circuit as it may conflict with the internal GFCI of the charger Generalandelectrical specifications Dock Charging power up to 7 6kW up to 32A Mains...

Страница 8: ...ted at a later time The Dock can be mounted on a suitable wall Included in delivery 1 Dock with 3 sealing plugs 1 installation instructions in English 3 round head screws 1 4 x 2 1 3 6 x 59 mm 3 unive...

Страница 9: ...Operating temperature 22 F to 122 F 30 C to 50 C full load Voltage supply 240 Volt AC split phase 32A at 7 6kW Power supply Max 40A configurable Connected load Up to 7 6kW maximum load PRODUCT OVERVI...

Страница 10: ...upply circuit to this device 2 Power supply line The cable routing plates may have to be switched over depending on whether the supply line is routed from the top or bottom 3 Ethernet cable Before con...

Страница 11: ...r possible a cable size no greater than 10 AWG 6 mm CAUTION When multiple charging points are to be installed every tenth must be provided with additional earthing Compatible electricalnetworktype Con...

Страница 12: ...he screws fully enter the channel strut nuts When fastening the Dock with the screws please make sure that the screws are fastened tightly into the bolt anchor wall To ensure adequate heat dissipation...

Страница 13: ...display You will also need a side cutter a pair of round nose pliers and for cable assembly a cable knife and a MultiStrip 13 INSTALLATION INSTRUCTIONS Drilling template Side cutter Round nose pliers...

Страница 14: ...loor Standard height 5 1 5m For full accessibility of charging only 3 9 1 15m DOCK INSTALLATION INSTRUCTIONS Information on mounting The Dock is secured through three screw holes to the wall To start...

Страница 15: ...an 5 16 8mm bit and insert the provided wall plugs If the provided screws are unsuitable for the wall type at the chosen location use another type of suitable fastener INSTALLATION INSTRUCTIONS CAUTI...

Страница 16: ...o integrate the charger in the customer s network It is important to know the connections on the interface board for the Ethernet connection 1 LAN 1 RJ45 charger communication over LAN 2a LAN 2 RJ45 d...

Страница 17: ...d using the step drill Drill step by step to ensure that the hole is not too large and that there is no leakage after the cable gland has been installed Insert the M20 cable gland 02 Replace the routi...

Страница 18: ...50 power plug and inserting it into a standard NEMA 14 50 outlet that is installed on a dedicated branch circuit with a 40 A circuit breaker in the feed panel If you choose to hard wire the unit to su...

Страница 19: ...1 After the electrical tests switch OFF the circiut breaker 2 Put the contact guard back onto the Dock 3 Use the provided seal to secure the contact guard on the Dock so that it is not possible to rem...

Страница 20: ...charger on port 1 on the left of the Dock After the electrical installation the charger can be clicked into the Dock Before mounting the charger make sure there is no voltage across the Dock by unplu...

Страница 21: ...and properly aligned strongly press the charger onto the Dock 06 If necessary readjust the locking bracket until it is properly aligned Alignment marks triangular recesses are visible on the locking c...

Страница 22: ...in place and the charger on the Dock 08 Power on the Dock circuit Assembly is done WARNING Make sure that the charger clicks correctly into the Dock Marking of the locking clip is in end position Set...

Страница 23: ...eed the Electrify America app Linking during installation for private use This step can be performed by the end customer or an electrician linking the charger with the Electrify America app this will...

Страница 24: ...itted the Ethernet cable to the local network Unscrew the cable gland s and remove the supply cable and if fitted the Ethernet cable s In the next step unscrew and remove the Dock Finally you may repl...

Страница 25: ...25 NOTES...

Страница 26: ...26 DOCK INSTALLATION INSTRUCTIONS...

Страница 27: ...hanged reproduced or distributed without the prior agreement issued in writing by Electrify America Electrify America LLC 2003 Edmund Halley Drive 2nd Floor Suite 200 Reston VA 20191 27 LEGAL NOTICE I...

Страница 28: ...8 06 19 Electrify America LLC 2003 Edmund Halley Drive 2nd Floor Suite 200 Reston VA 20191 In case of questions or problems with this product please call Electrify America Customer Assistance 1 833 53...

Отзывы: