For the oven burner, operate the oven burner at the minimum
position for 5 minutes, then open and close the oven door 2-3
times to check the flame stability of the burner. You do not need
to reduce the flame size for grill burners.
The position of the bypass screw must be loosened for conversion
from LPG to NG. For conversion from NG to LPG, the same
screw must be fastened. Make sure that the appliance is unpluged
from the electric mains and the gas supply is open.
Changing the gas inlet
For some countries, the gas inlet type can be different for NG/LPG
gases. In such a case, remove the current connection components
and nuts (if any) and connect the new gas supply accordingly. In
all conditions, all components used in gas connections should
be approved by local and/or international authorities. In all gas
connections, refer to the [“Assembly of gas supply and leakage
check”] clause explained before.
Thermostatic oven valve
Bypass Screw
Non-thermostatic oven valve
Bypass Screw