7-9
CONTROL SYSTEM
Revision Y05-01
Service Manual - EMD Series
3 Cooling
Mode
3.1 Cooling Mode – General
3.1.1
Mode Definition
MODE: COOL, AUTO (AT COOLING)
TEMP: SELECTED DESIRED TEMPERATURE.
FAN:
HIGH, MED, LOW, AUTO.
TIMER:
ANY
I FEEL: ON OR OFF
3.1.2
Room Temperature, RT, is detected by
x
RAT in normal operation, or
x
RCT (R/C sensor) in I-FEEL mode.
3.1.3
Indoor Coil Temp is detected by ICT.
3.1.4
Outdoor Coil Temp is detected by OCT.
3.2 Control Functions
3.2.1
COMP Operation
ON
OFF
RT-SPT
0
1
COMP
3.2.2
OFAN Operation
x
In normal operation OFAN operates together with the COMP.
3.2.3
IFAN Operation
x
IFAN will operate in ANY speed regardless the ICT or COMP state.
x
IFAN speed will be determined according to user selection or AUTO-FAN logic (sect. 2.2)
3.2.4
RV and HEATERS outputs
x
RV and HEATERS are in OFF state in cool mode.