PRODUCT DATA SHEET
2.3.3
WNG
18
DCI Specifications
Model Indoor Unit / Type
WNG
18
DCI / Wall Mounted
Installation Method
FLARE
Power Supply
V/Ph/Hz
220-240 / 1/ 50
INDOOR
Fan Type & Quantity
Crossflow *1
Airflow
(2)
Cooling / Heating
H/M/L
m
3
/hr
850
760
620
Sound Power Level
(3)
L - H
dB (A)
47 - 55
Sound Pressure Level
(4)
L - H
dB (A)
34 -43
Condensate Drain Tube I.D.
mm
16
Dimensions
W/H/D
mm
1060
295
210
Weight
kg
15
Package Dimensions
W/H/D
mm
1125
360
280
Stacking Height
Units
8
Heating Elements
kW
N/A
Moisture Removal
L/hr
2
2.3.4
ECF 9
DCI Specifications
Model Indoor Unit / Type
ECF 9
DCI / Cassette
Installation Method
FLARE
Power Supply
V/Ph/Hz
220-240 / 1/ 50
INDOOR
Fan Type & Quantity
Centifugal *1
Airflow
(2)
Cooling / Heating
H/M/L
m
3
/hr
530/600
500/530
435/450
Sound Power Level
(3)
Cooling / Heating
L - H
dB (A)
42-48 / 42-47
Sound Pressure Level
(4)
Cooling / Heating
L - H
dB (A)
32-38 / 32-37
Condensate Drain Tube I.D.
mm
16
Dimensions
W/H/D
mm
571
287
571
Weight
kg
22.7
Package Dimensions
W/H/D
mm
685
415
685
Stacking Height
Units
5
Heating Elements
kW
N/A
Moisture Removal
L/hr
1
NOTE:
1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
2-4
Revision
0
Содержание ECF12 DCI INV
Страница 14: ...4 1 OUTLINE DIMENSIONS Revision 0 4 OUTLINE DIMENSIONS 4 1 Indoor Unit WNG 9 12 DCI 4 2 Indoor Unit WNG 18 DCI...
Страница 15: ...OUTLINE DIMENSIONS 4 3 Indoor Unit ECF 9 12 18 DCI 4 4 Indoor Unit PXD 9 1 18 DCI 4 2 Revision 0...
Страница 16: ...OUTLINE DIMENSIONS 4 5 Indoor Unit LS 35 DCI 4 6 Outdoor Units TRIO QUATTRO DCI 0...
Страница 51: ...WIRING DIAGRAMS 8 WIRING DIAGRAMS 8 1 Outdoor Units TRIO QUATTRO DCI Revision 0 8 1...
Страница 87: ......