Drying
Drying mode where the temperature can be set in steps in the range from +16 to +30ºC.
The following is used as standard for new registrations: fan speed: 3, air swing: 1
SMS:
DRY 16~30
(E.g. DRY 18)
= 18ºC
NB! Check the drain hose of the heat pump before operation.
Fan speed
Change the fan speed regardless of the operating mode in steps from 0 to 5.
0=auto, 1-5 are different speed steps where 1=lowest speed and 5=highest speed
SMS:
Fans 0~5
(E.g. FANS 3)
= Fan speed level 3
air swing
Change air swing regardless of the operating mode in steps from 0 to 5.
0=Auto, 1-5 are directions in different steps where 1=Horizontal and 5=Vertical
SMS:
aiRs 0~5
(E.g. AIRS 2)
= Air Swing level 2
start / stop
Start or stop the heat pump operation. When restarted the heat pump always starts in
the last used operating mode before the pump was stopped; this applies also in case of
power failure.
SMS:
On
(E.g. ON)
= Starts the heat pump
SMS:
OFF
(E.g. OFF)
= Stops the heat pump
last sent command
Find out the last command you sent to your SMS-954.
SMS:
sEt?
(E.g. SET?)
= Receive a report back on the last
command sent.
temperature Readings
The remote control has a built-in sensor that senses ambient temperature.
For optimum temperature sensing, the remote control must never be placed close to the
front of the heat pump, nor should the sensor be covered since it would then be disturbed by
temperature fluctuations. With a text message the user can find out what the current
temperature in the place where SMS-954 is installed is.
SMS:
tgEt
(E.g. TGET)
= Current temperature status
(E.g. Received SMS:
”Confirm TMP:21C ADJ:+05TGET” = +21ºC with +0.5ºC adjustment)
temperature adjustment
If the temperature readings are misleading due to the location of the unit, it is possible to
adjust the readings so that they complies with one’s own measurements.
SMS:
taDJ XYY
(E.g. TADJ 120) = Negative correction of -2,0ºC
X = 0 for a positive value, X = 1 for a negative value
YY = 05 / 10 / 15 / 20 / 25 / 30 / 35
(Ex. 05=0.5ºC / 10=1.0ºC / 15=1.5ºC / 20=2.0ºC / 25=2.5ºC / 30=3.0ºC / 35=3.5ºC)
temperature alarms
Change the temperature value set for the temperature alarm. If the temperature is below a set
value 5 and +30ºC, SMS-954 will send an alarm to all phone numbers that have been
programmed. The factory setting upon delivery and the default setting is +5ºC.
SMS:
tEMP 05~30
(E.g. TEMP 09) = Send an alarm when the temperature is below +9ºC
nB:
If there is a temperature adjustment, SMS-954 will take it into consideration when sending
an alarm.
5
* The command works only on heat pump models equipped with this function.
Please see the operation manual to find out what the functions of your model are.