Test buttons
Best location
Once you have found the IR receiver on the indoor unit of the heat pump and mounted the remote
control unit, you can test the location by sending a command with the test buttons on the front side
of the unit. It is important to make sure that the area between the heat pump and SMS-954 is clear
during testing.
nB:
IR signals have a tendency to rebound from other objects. When installing SMS-954 under
the indoor unit of the heat pump, make sure to cover the front IR transmitter of the unit when
conducting tests to prevent the signal from rebounding from objects and giving misleading signals.
•
test button 1
Sends the following setting to your heat pump:
HEAT +8ºC degrees, fan speed: 5, air swing: 1.
•
test button 2
Sends the following setting to your heat pump:
HEAT +20ºC degrees, fan speed: 3, air swing: 1.
If the heat pump turns on, changes mode (depending on the setting in question) or peeps at
pressing an optional button, the location is good and SMS-954 can be mounted with the help of the
accompanying wall bracket.
See also the section “Heat Pump IR Receiver” on page 7.
location
SMS-954 communicates with the indoor unit of the heat pump via an IR transmitter and is equipped with two effective
transmitters – one on the front that sends the signal straight forward at a distance of up to 7 metres and another on top
that sends the signal straight up at a distance of approx. 1 metre. The transparent dome with the top IR transmitter can
be turned left or right up to 180˚ for the signal to be directed towards the IR receiver when located below the indoor unit
of the heat pump. NB: The range may vary depending on the location and the heat pump model.
Location
3