Your Elecro heater is factory set to accept input water flow entering on the left and 
exiting on the right, this can be reversed by rotating the flow switch 180° (i.e. ½ 
turn) (see diagram on following page).  

E

LECTRICAL

 C

ONNECTION

 

The heater must be installed in accordance with the country / regional requirements 
& regulations. In any event the work must be carried out by a qualified electrician, 
who will provide a certificate of conformity upon completion of the work.  
The power supply 

must

 be fitted with a RCD. 

 
Cable section: should be calculated at 5-amp / mm² for distances up to 20 metres 
(these sections are indicative and should be checked and adapted if necessary for 
cable lengths over 20 metres). 

P

OWER

 R

EQUIREMENTS

 

Power Output 

Volt (V) 

Amp 

2-kW 

230 

3-kW 

230 

13 

4.5-kW 

230 

20 

6-kW 

230 

27 

9-kW 

230 

40 

12-kW 

230 

53 

15-kW 

230 

66 

18-kW 

230 

79 

3 Phase 

 

 

9-kW 

400 

13 

12-kW 

400 

18 

15-kW 

400 

22 

18-kW 

400 

26 

Possible Cause 3.) Insufficient Flow. 
Confirm this by running the system with the cartridge removed from your pump & 
filter unit, this will supply the heater with the maximum flow rate your unit is capa-
ble of. If the heater then switches on (i.e. red light on) a blocked cartridge can be 
confirmed to be the cause. The cartridge should be cleaned or replaced.  
If using a sand filter check the pressure indicator on your sand filter and back wash 
if necessary  

Note; 

In some cases the high limit thermostat tripping and a low flow rate can be 

linked; When a filter becomes choked air can be drawn into the filtration system and 
become trapped inside the heater so causing the thermostat to trip. 

Possible Cause 2.)  The high limiting thermostat has tripped. 
Remedy; remove button cover and press red button to re-set (See diagram below).  
If a positive click is felt, the cause of the tripping 

must

 be investigated and could be 

caused by a debris build up or air pocket trapped inside the flow tube of the heater.  

Step 2 

- Push the red button 

Step 1 

- Unscrew the black cover 

T

ROUBLE

 S

HOOTING

 C

ONTINUED

 

No lights appear on the heater when it is switched on 

Possible cause: Power Failure external to the heater - Remedy:  
Check any fuses, RCD or other switch components installed in the supply cable.  

NOTE

: the heater is not fitted with a fuse. 