INFORMATION SCREENS
When the controlled is in the main screen and button 4 is pressed, screens with additional information will be displayed
consecutively.
First, the electricity consumption meters separately for the two tariffs are displayed and the date and time of their last reset.
While this screen is displayed, if button 4 button is held pressed for 2 seconds, the meters are reset and the reset date and
time are recorded.
The next pressing of ▼ button goes to
"WiFi connection"
screen with information on the status of the WiFi module.
The next pressing of ▼ button goes to a
"Version"
screen with information on the versions of the thermoregulator (and of
the WiFi module).
The next pressing of ▼ button goes to
"Smart Info"
screen, which displays additional information on the operation of the
water heater in “Smart Control” mode such as: electricity saved from the date last reset and the diagram for the warm water
consumption schedule for the current day, which will not be displayed if there is no schedule saved.
The next pressing of
button 4
goes to the screens with the electricity consumption schedule by time. The controller will
save this information for the last 8 days. By pressing ▲ or ▼buttons you change the graphs for the days for which there is
information available. Under each graph, the date to which it refers is displayed along with the electricity consumed for the
respective day. The information on consumed electricity is calculated on the basis of the set heating element power.
The electricity consumed graphs are followed by graphs with the average water temperature by time (hours).
FROST PROTECTION
When the water heater is in
"Standby"
mode or heating is disabled by a set timer, and the water temperature become 3°C
or fall below that value, the frost protection mode is enabled and the heating element is switched on. The operation mode
filed on the screen displays
"
".
When the temperature rises above 3°C, the frost protection mode is switched off.
Antifrost
WARNING!
This mode does not protect from freezing the water in the water mains, pipes and water connections outside
the water tank of the water heater.
ANTI-LEGIONELLA FUNCTION
"Anti-legionella" function is enabled by
"System Setup"
menu,
"AntiLegionella"
field. If water was
not heated up to 70°C for more than 7 days, the function is activated and water is heated up to 70°C,
then the function is automatically switched off. The function will not be activated if the
thermoregulator is in
"Standby”
mode. In order to minimize the electricity costs, this function
activates water heating one hour after the start of the Low Cost (second) tariff.
7
EN
EN
Содержание NHC-56M
Страница 32: ...RU RU 2 1 2 3 4 1 2 3 4 32...
Страница 33: ...NHC 56M TFT SmartControl WiFi 4 4 Smart 24 8 33 RU RU Smart Smart SL SL Flash...
Страница 35: ...35 1 4 1 Smart 4 Smart Smart Smart Smart 7 Smart 2 Powerful EN 814 814 2013 Smart Smart EN 814 RU RU...
Страница 36: ...t 3 10 24 10 10 0 7 4 1 36 RU RU...
Страница 37: ...4 4 2 WiFi WiFi WiFi Smart Smart 4 8 3 C 3 C 70 C 7 70 C 37 RU RU...
Страница 44: ...ELDOMINVEST Ltd 275A Vl Varnenchik blvd Varna 9009 Bulgaria Manufacturer...