Operation mode
Description
Antifrost
A frost protection mode is activated.
Standby
Off power state
Heating
"Heating" mode maintains the set temperature
Program
"Timers" mode with a weekly programmer operating in a mode of changing the set temperature.
Timers
"Timers" mode with set weekly programmer in on/off mode.
Smart Control
"Smart Control" mode operates depending on the priority set
Self-learning
"Self-learning" mode maintains the maximum temperature in the water heater and records
the hot water consumption for a period of one week
Error messages
Description
Wrong Time!
The clock of the thermoregulator is not set. The water heater can only be switched on in
the "Heating" mode. All the other modes are inaccessible.
Disconnected SL
The thermal sensor at the bottom of the water tank is turned off or disconnected.
The heating element will not operate and the water heater will not switch on unless the
problem is solved.
Short SL
The thermal sensor at the bottom of the water tank is short-circuited. The heating element
will not operate and the water heater will not switch on unless the problem is solved.
WH Frost
There is a danger of frozen water. The water heater will switch off.
Faulty heater
A probable failure of the heating element, because even though it is switched on,
the water temperature does not rise. The water heater will switch off.
Faulty flash!
Unable to save the changes in settings in the non-volatile memory of the controller.
TECHNICAL DESCRIPTION
NHC-56M is an electronic thermoregulator (controller) with a color TFT display designed for a water heater with the Smart
Control function and an option for a WiFi module enabling remote control.
The controller operates with one thermal sensor measuring the temperature at the bottom of the water tank. The
thermoregulator is controlled by 4 multifunctional buttons and has clear and intuitive control and setting menus. The
graphic display shows diverse information on the operation and condition of the water heater. Additional extras are the
keeping of date and time, the sounding of a signal when pressing buttons or when an alarm is activated, Anti-legionella
function, Frost protection function for the water in the tank, etc. The thermoregulator has 4 main operation modes:
"
- off state,
"Heating"
– to maintain a set temperature,
"Smart Control"
– a self-learning mode with automatic
Standby"
selection of the heating temperature intended to make maximum energy cost savings and
"Timers"
mode, which allows
the user to control the water heating algorithm. The thermoregulator has a
„Delayed Start“
function enabling a switched in
"
water heater to be switched in
"Heating"
mode in a time set by the user, within 24 hours from the current
Standby"
moment.
In the event of power outage, the thermoregulator will save the current operation mode, settings, time and date.
WARNING!
This appliance may be used by children above 8 and persons with limited physical, sensory and mental
abilities, or with insufficient experience and knowledge, if they are supervised or instructed on the safe use of the appliance
and understand the dangers. Children should not play with the appliance. Children are prohibited to clean or service the
appliance.
3
EN
EN
Содержание NHC-56M
Страница 32: ...RU RU 2 1 2 3 4 1 2 3 4 32...
Страница 33: ...NHC 56M TFT SmartControl WiFi 4 4 Smart 24 8 33 RU RU Smart Smart SL SL Flash...
Страница 35: ...35 1 4 1 Smart 4 Smart Smart Smart Smart 7 Smart 2 Powerful EN 814 814 2013 Smart Smart EN 814 RU RU...
Страница 36: ...t 3 10 24 10 10 0 7 4 1 36 RU RU...
Страница 37: ...4 4 2 WiFi WiFi WiFi Smart Smart 4 8 3 C 3 C 70 C 7 70 C 37 RU RU...
Страница 44: ...ELDOMINVEST Ltd 275A Vl Varnenchik blvd Varna 9009 Bulgaria Manufacturer...