Valid for firmware revision 1.00 and above
CIM-130&136-KLRV MAN - EN – p.
16 of 16
- pump protection exclusion
POSSIBILITY OF SWITCHING OFF THE PUMP PROTECTION
To switch off the
pump protection,
key in
010
on the
mobile phone.
After the switch
off command,
the following
is displayed:
INTERMITTENT
SIGNALS
Reply message from control unit to mobile
phone:
PUMP PROTECTION EXCLUDED
To delete this
switching off,
key in
011
on the
mobile phone.
After the command
to delete switching
off, the following is
displayed:
SIGNALAS
OFF
Reply message from control unit to mobile
phone:
ACTIVE PUMP PROTECTION
Example:
WATER PRESSURE
6,8 Bar
PRESSURE SWITCH
4,5 Bar
TIMER
10:15
SETTING OF THE MINUTES OF WORK
(TIMER)
To set the minutes
(minimum 1’ max 1440’)
of work of the motor
pump key in on the
mobile phone:
500# .....
Minutes of work
example=
500#120
(2 hours of work)
Wrong examples=
500 space = 120
space 500 # 120
500 o 120
500 # 1441
After the command the following is
displayed.
Reply message from control unit to
mobile phone:
OK, timer set to...h...min
If the setting is correct.
ERROR
timer setting not correct.
SETTING OF THE WORKING PRESSURE
The working pressure can be set through
an SMS command.
The engine must be running. To set the
working pressure write
on the mobile, for example:
600#6.1
The control unit will automatically set
the pressure of the motor pump to 6.1
Bar. The lowest settable value is 1 Bar
while the highest value is 21 Bar. The
control unit accepts these types of SMS:
600#6,1
600#6
600#6,11
After the command the following is
displayed.
Reply message from control unit to
Mobile phone:
“OK, pressure set to 6.1 Bar”
If the setting is correct.
“ERROR
pressure setting not correct.”
If the setting is not correct.
Working time
(MINUTES)
HOURE OF
OPERATION
BAR STORED