4.9
Positioning units for station with damped pneumatic stoppers
Every 1000 hours:
Lubricate the positioning unit fingers with a film of grease.
Use grease ref. 800 00 002 (Crown ref. 7041 spray).
Check the lubrication of the guiding shafts:
To reach the guiding shafts, remove the central fastening screw from the plate to release it from the
positioning unit without removing the positioning unit from the transfer system.
For a quick lubrication of the guiding shafts, it is also possible to access them, without any
disassembly, only by pulling the plate.
Changing the pins (locating/centering pins):
Extract the previous pins from the press.
Install the new pins in the press while using a bush of a workpiece carrier ref. 120 03 006 as a support
(insert the pin in the bush and then place them on the positioning unit plate).
4.10
Lift positioning units with damped pneumatic stoppers