ELCART 09/08500-00 Скачать руководство пользователя страница 5

ELCART

ELCART DISTRIBUTION SPA  via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY

Tel. +39 02.25117310 Fax +39 02.25117610 sito internet:  www.elcart.com    e-mail: [email protected]

Manuale di istruzioni/Scheda tecnica

La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.

The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.

La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.

ART. 09/08500-00

PAGINA 5 DI 6

3. OPERATING INSTRUCTION

3.1 MEASURING CURRENT

1. Set the rotary switch at desired A~ range position. 

Press the trigger to open the transformer jaws and clamp 

onto one conductor only (Fig.1), The transformer jaws pick 

up the AC current flowing through the conductor.

2. When only the figure “1” displayed, it indicates overrange

situation and the higher range have to be selected.

WRONG                  CORRECT

Fig 1.

3.2 INSULATION TEST

(Option 500V insulation tester unit)

1. Connect the insulation tester unit VΩ, COM, EXT three-

banana plugs to the clamp meter VΩ, COM, EXT.

2. Set the rotary switch of clamp meter at 2000MΩ position.

3. Set the insulation tester unit range switch to the 2000MΩ 

position.

4. Uses the insulation tester unit of the test leads connects 

its L, E input connect to being tested installations. 

(Test installation's must be power OFF)

5. Set the insulation tester power switch to the ON position.

6. Depress the PUSH 500V push-push switch; the 500V on 

red LED lamp will light. Clamp meter display reading is the 

insulation  resistance  value.  If  the  reading  is  below  19MΩ 

change  clamp  meter  and  insulation  tester  unit  to  20MΩ 

range, can be increasing the accuracy.

7. If the insulation tester unit is not use, the power switch 

must shift to power OFF position, and the test leads must 

leave the E. L input connect. That can be increase battery 

life and prevent electrical shock hazard.

3.3 MEASURING VOLTAGE

1. Connect the black test lead to the COM jack and the red 

test lead to the VΩ jack.

2. Set the rotary switch at the desired V or V~ range position 

and connect test leads across the source or load under 

measurement. The polarity of the red lead connection will 

be indicated along with the voltage value when making DC 

voltage measurement.

3. When only the figure“ 1 ”is displayed, it indicates over 

range situation and the higher range has to be selected.

3.4 MEASURING RESISTANCE

1. Connect the black test lead to the COM jack and the red 

test lead to the VΩ jack.

2. Set the rotary switch at desired Ω position and connect 

test leads across the resistor under measurement.

NOTE:

1. If the resistance being measured exceeds the maximum 

value of the range selected or the input is not connected, an 

over range indication “1” will be displayed.

2. When checking in - circuit resistance, be sure the circuit 

under test has all power removed and that all capacitors 

have been discharged fully.

3.5 TESTING DIODE

1. Connect the black test lead to the COM jack and the red 

test lead to the VΩ jack. (The polarity of red lead is “+”)

2. Set the rotary switch at  position and connect red lead 

to the anode, black lead to the cathode of the diode under 

testing. The meter will show the approx. forward voltage of 

the diode. If the lead connection is reversed, only figure “1” 

displayed.

3.6 CONTINUITY TEST

1. Connect the black test lead to the COM jack and the 

red test lead to the VΩ jack. (The polarity of the red lead is 

positive“ + ”)

2. Set the rotary switch at  position and connect test leads 

across two points of the circuit under testing. If continuity 

exists (i.e., resistance less than about 100Ω), built -in buzzer 

will sound.

WARNING

To avoid electric shock, be sure the thermocouple has been 

removed before changing to another function measurement.

3.8 MEASURING FREQUENCY

1. Connect the black test lead to the COM jack and the red 

test lead to the VΩ jack.

2. Set the rotary switch at Hz position and connect test leads 

across the source or load under measurement.

NOTE:

1. Reading is possible at input voltage above 10V rms, but 

the accuracy is not guaranteed.

2. In noisy environment, it is preferable to use shield cable 

for measuring small signal.

4. SPECIFICATIONS

Accuracy is specified for a period of one year after calibration 

and at 18℃ to 28℃ ( 64℉ to 82℉) with relative humidity 

to 80%.

4.1 GENERAL

Display:   3 1/2 digit LCD, with automatic polarity indication

Terminals and earth ground: 1000V dc or 750V rms ac (sine)

Measuring Method:   Dual-slope integration A-D converter 

Over range Indication:  

”1” Figure only in the display

Polarity indication:  

”-”displayed for negative polarity

Operating Temperature:  

0℃ to 40℃ (32℉ to 104℉)

Storage Environment:  

-10℃ to 50℃(14℉ to 122℉)

Power:  

9V alkaline or carbon-zinc battery

  

(6F22 or equivalent)

Accessories:  

Operating manual, set of test leads

Low Battery Indication:  

”BAT” to left of display

Dimension:  

96(W)x235(D)x46(H) mm

Weight:  

330gr. (including battery)