background image

ELCART

ELCART DISTRIBUTION SPA  via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY

Tel. +39 02.25117310 Fax +39 02.25117610 sito internet:  www.elcart.com    e-mail: [email protected]

Manuale di istruzioni/Scheda tecnica

La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.

The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.

La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.

ART. 09/08500-00

PAGINA 4 DI 6

DIGITAL CLAMP METER 

OPERATOR’S INSTRUCTION MANUAL

1. SAFETY INFORMATION

The meter is completely portable, LCD, 3 1/2 digit clamp 

meter with insulation test function (with option 500V 

insulation tester unit). It has been designed according to 

IEC1010-1 IEC1010-2-032 concerning electronic measuring 

instruments with an overvoltage category (CAT II 1000V & 

CAT III 600V) and pollution 2 and safety requirements for 

hand-held current clamps for electrical measurement and 

test.

Follow all safety and operating instructions to ensure that the 

meter is used safely and is kept in good operating condition.

1.1 PRELIMINARY

When using this meter, the user must observe all normal 

safety rules concerning:

Protection against the dangers of electronic current.

Protection of the meter against misuse.

Full compliance with safety standards can be guaranteed 

only if used with test leads supplied. If necessary, they must 

be replaced with the same model or same electronic ratings. 

Measuring leads must be in good condition.

1.2 DURING USE

Never exceed the protection limit values indicated in 

specifications for each range of measurement.

When the meter is linked to measurement circuit, do not 

touch unused terminals.

When the value scale to be measured is unknown 

beforehand, set the range selector at the highest position.

Before rotating the range selector to change function, 

disconnect test leads from the circuit under test.

When carrying out measurements on TV or switching power 

circuits always remember that there may be high amplitude 

voltage pulses at test points, which can damage the meter.

Never perform resistance measurements on live circuits.

Always is careful when working with voltage above 60VDC 

or 30VAC rms. Keep fingers behind the probe barriers while 

measuring.

1.3 SYMBOLS
 

Important safety information, refer to the operating  

 manual.

 

Dangerous voltage may be present.

             Double insulation (Protection class II).

  

 

Application around and removal from HAZARDOUS  

 

LIVE conductors is permitted.

 

Earth ground.

1.4 MAINTENANCE

Before opening the meter, always disconnect test leads 

from all sources of electric current.

If any faults or abnormalities are observed, the meter cannot 

be used anymore and it has to be checked out.

Never use the meter unless the back cover and the battery 

cover are in place and fastened fully.

Do not use abrasives or solvents on the meter, use a damp 

cloth and mild detergent only.

2. DESCRIPTION

This meter is one of a series portable 3 1/2 digital clamp 

meter for measuring DC and AC Voltage, AC current, 

resistance, continuity test and insulation test. 

Full overload protection, Low battery indication and over-

range indication are providing. 

Following table shows function of the series of clamp meter:

1. TRANSFORMER JAWS

2. BARRIER OR TACTILE INDICATOR

3. DATA HOLD SWITCH

4. TEMPERATURE MEASURING SOCKET

5. ROTARY SWITCH

6. LCD DISPLAY

7. DROP-PROOF WRIST STRAP

8. INPUT JACKS

9. TRIGGER

2.1 FUNCTION AND RANGE SELECTOR

A rotary switch is used to measurement functions and 

ranges. 

When the switch is set to OFF position, the meter does not 

operate.

2.2 TRANSFORMER JAWS

Pick up the AC current flowing through the conductor. 

Press the TRIGGER to open the transformer jaws. 

When  the  finger  press  on  the  TRIGGER  is  released,  the 

jaws will close again.

2.3 DATA HOLD

Depress  HOLD  Button  Switch  to  toggle  in  and  out  of  the 

Data Hold mode. 

Releasing Data Hold mode again press the button.

2.4 INPUT JACKS

This meter has three input jacks that are protected against 

overload to the limits shown.

During use connect the black test lead to COM jack and 

connect red test lead to VΩ jack. 

The red test lead is depended on function selected.

The EXT jack is used for accept insulation tester unit EXT 

banana Plugs, when measurement insulation resistance.

1

3

2

4

5

6

7

8

9