ENG man BRAVO-FUNK-915 00
BRAVO-FUNK-915 Radio remote control system
- Page 14 -
5.3 MODIFYING THE PROPORTIONAL FUNCTION PARAMETERS (SETUP)
The parameters of the proportional functions can be changed by applying the SETUP procedure and involves the
modification of the following parameters:
-
Calibration of maximum and minimum values of each proportional function with output in voltage or in current (PWM).
-
Calibration of proportional values in voltage in rest position (OFFSET).
-
Inversion of movement direction of the Joystick axle.
-
Reset to default Factory settings.
SETUP enabling.
Before proceeding to change the parameters of the proportional functions, it is necessary to enable the SETUP function.
-
Open the receiver cover.
-
Power the receiver.
-
Press the SETUP button inside the receiver on the LED card.
-
The yellow SETUP LED is on fixed.
Receiving
SETUP button
SETUP LED
P+/P- selector
Change maximum value.
-
With the SETUP function enabled, check that all the proportional functions are in rest position. For the potentiometers,
the rest position is with the potentiometer rotated counter-clockwise. Proportional functions out of zero prevent
proper operation of the SETUP function. The presence of two or more proportional functions simultaneously out of
zero is indicated by the rapid flashing of the SETUP LED.
-
Move the Joystick of the function you want to adjust to the maximum and hold it in position.
-
By operating the selector in which P+ / P- is indicated, you will change the maximum value of the function by either
increasing or decreasing it.
-
Press the STOP pushbutton to save the changed value. Switch off the receiver to cancel any changes.
Change minimum value.
-
With the SETUP enabled, move the Joystick of the function you want to adjust just slightly out of zero and hold it in position.
-
By operating the selector in which P+ / P- is indicated, you will change the minimum value of the function by either
increasing or decreasing it.
-
Press the STOP pushbutton to save the changed value. Switch off the receiver to cancel any changes.
Adjustment of the values at rest of the outputs in voltage (OFFSET).
-
With the SETUP function enabled, check that all the proportional functions are in rest position. The presence of two
or more proportional functions simultaneously out of zero is indicated by the rapid flashing of the SETUP LED.
-
On the Transmitter, activate and release the selector with P+/P- indicated from the P+ side and immediately after
activate and release the Start command.
-
Repeat the operation described above until the SETUP LED starts blinking three times.
-
Move the Joystick or the potentiometer of the function you want to adjust just slightly out of zero and hold it in position.
-
By operating the selector in which P+ / P- is indicated, you will change the OFFSET value of the function by either
increasing or decreasing it.
-
Press the STOP pushbutton to save the changed value. To perform other adjustments, bring the Stop in rest position,
press Start and resume operations from the two points described above we have just discussed. Switch off the
receiver to cancel any changes.
-
To exit the adjustment mode of the Offset voltage, it is necessary to exit the SETUP mode, switching the receiver off
or moving the Elca Logo of the cable protection hood for approximately 10 seconds near to the area on the receiver
indicated with Enable SETUP.