4.3. Control box 

Control box is placed on back rest drive unit. In case 

of failure of any component, there are installed special 
systems blocking adjustment functions. Control box is 
protected  against  ingress  of  moisture  and  overload 
protection system:  

• 

limit  switches  turn  off  drives,  when  they  get  to 
the limit position, 

• 

thermal switch turns off control box if it overheats. It should be ready 
to re-use after 30 minutes break. 

The EPR mains cable is fitted with a push-on anti-kink device and tension 

protection. 

4.4. Hand switch 

The electrical adjustment can be made using the hand 

switch. Functions can be controlled by the press of the 
button on keypad on the front side. The fixing bracket 
on the rear of the hand switch can be used to hold it in 
an  easily  reachable  position  on  the  nursing  bed. 
Operating of hand switch is described in subclause 7.1. 

5.0. Accessories and spare parts 

Warnings 

 

Use  only  original  Elbur  accessories  and  spare  parts 

  modification  of 

nursing beds is strictly forbidden without authorization of our company. 

 

It  is  necessary  to  perform  specific  control  tests  after  modifying  the 
nursing bed to make sure that it is going to work properly. 

Accessories  and  spare  parts  can  be  ordered  from  distributor  or  Elbur 

company. For reasons of safety, it is allowed to use only original spare parts                          
or  accessories  from  Elbur  sp.  z  o.o.  sp.k.  Otherwise,  our  company  will 
assume  no  liability  for  any  accidents,  damage,  injury  and  risks  that  come 
about through the use of other spare parts or accessories.  

6.0. Assembly 

Before commencing assembly of the nursing bed, please read carefully 

instruction manual and verify the shipment contents with your order. Please 
contact  your  distributor  or  Elbur  customer  service,  if  you  miss  any  items            
or get something in bad condition.  

Warnings 

 

Two people 

qualified in nursing bed’s operating are 

required to assembly. 

 

In  order  to  avoid  wrong  assembly,  read  carefully  instruction  manual         
and labelling on the bed. Remember also to use proper tools. 

Содержание B 521 II

Страница 1: ...INSTRUCTION FOR USE ELBUR Nursing Beds PB 521 II PB 526 II ELBUR PB 521 II ELBUR PB 526 II...

Страница 2: ......

Страница 3: ...ty of our products In order to meet customer expectations we provide wide range of bed height adjustment We also care about attractive design as well as matching furniture systems and accessories whic...

Страница 4: ...es 11 2 3 1 General information 11 2 3 2 Electrical components information 12 2 3 3 Information for care personnel 12 2 3 4 Assembly information 13 2 3 5 Service information 13 3 0 Scope of delivery 1...

Страница 5: ...6 12 Assembly of the lifting pole 21 7 0 Operating of the nursing bed 21 7 1 Electric mattress support adjustment 22 7 2 Side rails operating 23 7 3 Setting the springiness of mattress support platfor...

Страница 6: ...rective 93 42 EEC concerning medical devices EN 60601 1 Medical electrical equipment Part 1 General requirements for basic safety and essential performance EN 60601 2 52 Medical electrical equipment P...

Страница 7: ...20 Conditions operating storage Temperature o C 10 40 Humidity 30 75 Temperature o C 5 45 Humidity 30 75 Mattress Dimensions HxWxL 10x90x200 cm 12x90x200 cm Volume density of foamed material 35 50 kg...

Страница 8: ...barcode max patient weight safe working load manufacturer information and warning symbols 1 3 2 Information labeling Max Patient Weight 140 kg for PB 521 II this value is 165 kg Safe Working Load 175...

Страница 9: ...pplication part type B according to EN 60601 1 electrical appliance class II double insulated ingress protection of electrical parts from splashwater do not use the medical device outdoors product mus...

Страница 10: ...any time It is necessary to contact physician in charge to make sure that there are not any limitations of use nursing bed in daily healthcare Due to the design ELBUR nursing beds are only approved f...

Страница 11: ...in proper and faultless condition Only use technically perfect bed Contact manufacturer or distributor if the exchange or repair of faulty parts have to be made If damage or malfunction is suspected...

Страница 12: ...cable is damaged that there is no loop in the cables and that they are not crushed by moving parts or components of other devices It is essential to leave the nursing bed unused for at least 18 minut...

Страница 13: ...stomer service 2 3 4 Assembly information Warnings Read instruction carefully before commencing assembly Verify the shipment contents with your order before commencing assembly to make sure that you h...

Страница 14: ...contact your distributor or Elbur customer service if you miss any component or get something in bad condition Scissor lift with drive unit Different models are available to order without castors on k...

Страница 15: ...done by manufacturer 4 2 Back rest foot rest drive units Nursing beds described in this instruction manual have one drive unit used to adjust back rest section and one drive unit used to adjust upper...

Страница 16: ...es and spare parts Warnings Use only original Elbur accessories and spare parts modification of nursing beds is strictly forbidden without authorization of our company It is necessary to perform speci...

Страница 17: ...d boards out of the box bring all accessories side rails drive units and all other components out of the box remove all unnecessary package s items 6 3 Assembly of mattress support platform on the sci...

Страница 18: ...pport platform scissor lift lugs then connect it using quick release bolts 6 4 Location of drive units and control box for mattress support platform Warning Take special care in assigning the drive un...

Страница 19: ...n drive unit is fixed under mattress support platform with the motor housing towards the head end board label on the bed align holes in holders and the drive insert the quick release bolt and secure b...

Страница 20: ...t functions ensure that the cables and wires cannot be damaged or overstretched The nursing bed should be plugged in to the separate socket during the tests There must be enough space for bed height a...

Страница 21: ...t Warning Wrong assembly of the side rails does not let to achieve required distance from the top of the mattress to the top edge of the top side rail which can caused patient s entrapment or falling...

Страница 22: ...adjustment range of height or angle of mattress support platform is possible only within a predetermined range The electrical adjustments can be made using the hand switch which functions are describ...

Страница 23: ...rails during lowering them to avoid rapid decrease The ends of side rails shall be always at the same level of mattress support platform head section and foot section Lowering height of mattress suppo...

Страница 24: ...different position follow safety rules indicated below mattress support platform has to be in flat and horizontal position side rails has to be latched and in upper position unplug the mains power cab...

Страница 25: ...olt out of the hole in the mounting holder then first person can carefully lower the back rest to the flat position To convert the bed back to its normal operating state the quick release bolt has to...

Страница 26: ...c components 4 Drive units Housings should be wiped only with a slightly moisturized cloth 9 0 Service Warnings Only specially authorized technicians are allowed to carry out troubleshooting activitie...

Страница 27: ...t inspection Repeat inspection Inspection following repairs servicing Manufacturer s final inspection Electrical appliance class I II Manufacturer Elbur sp z o o sp k Bed type PB _____________________...

Страница 28: ...ease bolts mounting drive units fitted properly YES NO Is lifting pole distorted YES NO Is triangle grab handle still good enough to use YES NO 1 2 Visual inspection of the electrical components Is th...

Страница 29: ...re control and blocking functions of the hand switch working properly YES NO Are drive units working properly abnormal noises smooth operation YES NO 3 2 Performance check of the mechanical components...

Страница 30: ...__________________________________________________________ ____________________________________________________________ Comments ____________________________________________________________ __________...

Страница 31: ...after 30 minutes break from using adjustment functions Disabler in the hand control activated Deactivate disabler turn key to the left Hand control damaged Notify customer service Control box damaged...

Страница 32: ...perfect condition Technical specifications subclause 1 2 contain guidance of operating and storage conditions for ELBUR nursing beds Nursing bed shall be protected from destruction under external infl...

Страница 33: ...__________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______...

Страница 34: ...ELBUR PB 521 II PB 526 II Elbur sp z o o sp k 34 of 36...

Страница 35: ......

Страница 36: ...Elbur sp z o o sp k Dzia osza 34 56 500 Syc w POLAND Tel 48 62 786 97 80 e mail info elbur eu www elbur eu E TF 2E 13 01 02 11 2020...

Отзывы: