Precautions  

For a safer use of the product and to optimize the lifespan of the product, we recommend you 

to follow the precautions below:

The wireless accessories must be connected to the control panel.

Low power voltage may affect transmission distance.

Do not press the SOS key on the remote control if it is unnecessary to avoid

     

disturbing 

neighborhood.

-    Check  the  system  regularly  to  make  sure  the  system  works  properly.

-    The  control  panel  is  neither  waterproof  nor  moisture-proof,  install  it  in  a  shady, 

      cool  and  dry  place.

-    The  case  of  the  control  panel  is  made  of  ABS  plastic.  Keep  away  from  bright  light  for

      a  longer  lifespan.

-      The  control  panel  is  not  explosion-proof.  Keep  away  from  fire  and  flames.

-      Install  the  control  panel  away  from  objects  such  as  heater,  air  conditioner, 

        microwave  oven  etc.  that  generate  heat  or  electromagnetic  fields.

-      Dispose  of  the  batteries  according  to  local  regulations.

-      Dismantling  of  this  product  must  be  done  by  professional  personnel  only.

Standards

   

This product bears the selective sorting symbol for waste electrical and electronic equipment 

(WEEE).  This  means  that  this  product  must  be  handled  pursuant  to  European  Directive 

2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment.

For further information, please contact your local or regional authorities.

Electronic products not included in the selective sorting process are potentially dangerous for the 

environment and human health due to the presence of hazardous substances.

In compliance with European laws. This product is in compliance with the essential requirements 

and other relevant provisions of Directive 1999/5/EC. 

This product was designed and manufactured in compliance with Directive 2002/95/EC of the 

European Parliament and of the Council on the restriction of use of certain hazardous substances 

in electrical and electronic equipment (RoHS Directive - RoHS) and is deemed to comply with 

the maximum concentration values set by the European Technical Adaptation Committee (TAC).

Manufactured in China.

ST-SK1

-C-UM-EN20141120-1.0-W

Содержание ST-SK1

Страница 1: ...I N S T A L L A T I O N M A N U A L GSM Alarm Security System ST SK1...

Страница 2: ...ency 850 900 1800 1900 mHz Radio frequency 433 92MHz 75KHz Transmission distance 80m in open space Standby current 80ma Alarm current 300mA Backup batteries Lithium Batteries 3 7V 800 mAh x 2 BL 5B 8h...

Страница 3: ...panel on the wall make sure the reception of the GSM signal is sufficient Fix the wall mounting bracket on the wall with screws Wedge the panel on the bracket make sure they fit well Basic Operations...

Страница 4: ...necessary to set up your system 123456 User code necessary to disarm your system or stop the alarm 1234 Duress code 0000 enables you to trigger a duress alarm Open door code 8888 enables you to open a...

Страница 5: ...added the countdown starts over from 30 so that you can register another RFID tag in control panel up to 50 tags can be registered in the control panel Press Esc to exit Delete all 1 YES 0 NO Delete...

Страница 6: ...tem Setting Control by Phone ON or OFF You can activate or deactivate the control of your system by phone call Activating the control by phone call enables you to arm and disarm the system and monitor...

Страница 7: ...silently Default setting On Wireless Siren Siren Switch ON OFF Enable Disable the siren Default setting On Wireless siren refers to a siren connect ed to the control panel by radio fre quency Arm Disa...

Страница 8: ...nly after having enabled it from the control panel as explained on page 10 of this manual Method 1 When an alarm has been triggered the control panel dials the stored phone numbers When you pick up th...

Страница 9: ...he control panel The speech bubbles that follow are the dialogue between the user and the control panel SMS sent by the user are in blue SMS sent by the control panel are in grey The system is in Engl...

Страница 10: ...e Zones names 1 Entrance door sensor Ok Note Zones 1 to 9 can be renamed The name of the zone cannot consist of more than 30 Latn characters Zones 10 to 99 cannot be renamed SMSAlertforAccessoryLowBat...

Страница 11: ...ste then edit case sensitive Ok Note Thisfunction can be used if you do not want to bring a remote control or a RFID tag with you When you arm the system the system will be armed after the delay set W...

Страница 12: ...OS Disarm LED indicator Arm the system Press the Arm button to arm the alarm system The LED indicator lights up the control panel beeps once The system is armed If an intruder is detected the siren ri...

Страница 13: ...ea Radio frequency 433MHz 75KHz Housing material ABS plastic Operating conditions Temperature 10 C 55 C Relative Humidity 80 non condensing Dimensions 57 x 31 x 11 mm Design 3 1 2 1 LED indicator 2 De...

Страница 14: ...s Fix the bracket on the wall with screws and attach the detector to the bracket Adjust the bracket to change the detection distance and angle It is recommended to mount the detector 2 2 m from the gr...

Страница 15: ...rol panel To check if the registration is complete arm the system and separate the magnet from the transmitter again by opening the door or window on which it is installed If the siren rings out the r...

Страница 16: ...When attempting the connection the control panel beeps twice The accessory has already been connected Make sure you do not trigger any other accessory when connecting one accessory to the control pan...

Страница 17: ...one by professional personnel only Standards This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to...

Страница 18: ...ELBRO AG Gewerbestrasse 4 CH 8162 Steinmaur Switzerland www elbro com...

Отзывы: