28
TABLE FOR THE CHOICE OF THE INJECTORS
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION
(2 m
3
/h kW)
BRULEURS
Air necessary for combustion [m
3
/h]
A
uxiliary
(A)
1,80
Semi-rapid (SR)
3,10
Rapid burner (R1)
6,10
Rapid burner (R2)
5,10
Thermostat oven
6,40
Grill
4,00
TABLE FOR THE CHOICE OF THE INJECTORS
G 30 – 30 mbar
G 20 – 20 mbar
G 110 – 8 mbar
(L.P.G.)
(NATURAL GAS)
(TOWN GAS)
BURNERS
Rating
Reduced
Ø mm
mm ring
Ø mm
mm ring
Ø mm
mm ring
type
Watt
power [W]
injector
opening
injector
opening
injector
opening
A
900
300
0.47
3
0.70
1.5
1.30
1
SR
1550
380
0.62
5.7
0.88
2
1.70
1,5
R 2550 500 0.78 6.5 1.15 2 2.20 1,5
DR 3500 850 0.92
Fully open
1.35 5 2.80 5
OVEN
3200
850
0.86
Fully open
1.30
5
2.70
5
GRILL
2000
–
0.72
Fully open
1.05
9
2.15
9