Gas connection with rigid or flexible pipe
Note: if already fitted on the inlet pipe,
remove the rubber hose holder
Manifold
male
pipe fitting
Inlet pipe
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) female
1/2” G cylindrical
(ISO 228-1) female
Sealing
washer (#)
Flexible pipe
(not supplied)
Rigid pipe
(not supplied)
Fig. 2.3
(#) If not already fitted on the inlet pipe,
it is supplied with the appliance in a
separate kit
GAS MAINTENANCE
For the gas category check the data label attached on the appliance.
TABLE FOR THE CHOICE OF THE INJECTORS
Cat: I 3+
G30/G31
28-30/37 mbar
BURNERS
Nominal power
[kW]
Reduced power
[kW]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,40
50
Semi-rapid (SR)
1,75
0,45
65
Rapid (R)
3,00
0,75
85
Double-ring compact (DCC)
4,00
1,50
100
Dual (D)
inner crown
0,80
0,40
44
outer crown
4,20
(3,80 at G30/G31)
1,50
98