18
Display code: 9
It takes to long before a win is registered. Check the
settings in the menu “Payout information” and also check
the working of the prize detector.
Display code:10
This warning appears when there are too much accidental
wins.
Display code: 12
The payout fluctuates above 100%. Check the settings and
your claw settings and keep an eye on the payout.
When the problem persists, an error will be shown.
Display code: 13
The coin- or bill acceptor has reported a problem.
Display code: 14
By switching on the crane, the detector becomes active.
Objects in the prize hole or a problem with the detector can
cause this.
Remark: the controller can’t determine whether the
detector works correctly.
Display code: 15
This warning will appear when the number that was set
under ‘prizes/dispenser alarm’ is exceeded.
Display code: 16-26
The system has detected a mechanical error. You can
check these errors in the menu ‘Mechanical diagnostics’.
Display code: 31
The controller can’t change the meters or is defect.
Display code: 32
The dispenser does not give a signal when a payout is
made. The dispenser, the controller or the cable can be
damaged.
! WARNING:
it took to long many
games to win (check
settings and
detector)
! WARNING:
payout over 100%
check (claw finger)
settings
! WARNING:detector
obstructed or non-
functioning properly
Press S to resume
! ERROR: meters
disconnected or
circuit defect
Press S to resume
! ERROR: dispenser
payout was not detect
in time
Press S to resume
! WARNING :
prizes or dispenser
low
! WARN : mechanical
critical operation.
Check diagnostics for
more info.
! WARNING : grabber
too powerfull!
Set -5% or change
type. Press S to
resume
! warning: coin or
bill acceptor
obstructed Press S to