background image

2

©2020 ELATION PROFESSIONAL

 all rights reserved. Information, specifications, diagrams, images, and 

instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying 
product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection 
claimed includes all forms and matters of copyrightable materials and information now allowed by 
statutory or judicial law or hereinafter granted.  Product names used in this document may be trademarks 
or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION 
brands and product names are trademarks or registered trademarks of their respective companies.

ELATION PROFESSIONAL

 and all affiliated companies hereby disclaim any and all liabilities for property, 

equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic 
loss associated with the use or reliance of any information contained within this document, and/or as a 
result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation 
of this product.

Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040

323-582-3322 | 323-832-9142 fax | 

www.elationlighting.com

 | 

[email protected]

Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands

+31 45 546 85 66 | +31 45 546 85 96 fax | 

www.elationlighting.eu

 | 

[email protected]

Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000

+52 (728) 282-7070

D O C U M E N T   V E R S I O N

Due to additional product features and/or enhancements, an updated version of this 
document may be available online. Please scan the QR Code with your mobile device or 
visit 

www.elationlighting.com

 for the latest revision/update of this manual, before 

installation and/or programming.

Date

Document

Version

Software Version ≥ DMX Channel Modes

Notes

02/2015

1

≥1.02

6/7/8/12

Initial Release

12/08/2021

2

N/C

N/C

Update Format

Содержание SIXPAR 300

Страница 1: ...SIXPAR 300 user manual...

Страница 2: ...economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging a...

Страница 3: ...arranty USA Only 5 Safety Guidelines 6 Overview 8 Installation 9 DMX Setup 12 RDM Setup 14 System Menu 15 Dimmer Mode 17 DMX Channel Functions and Values 18 Maintenance Guidelines 20 Specifications 21...

Страница 4: ...upport team for further instructions Please do not return this device to your dealer without first contacting customer support Please do not discard the shipping carton in the trash Please recycle whe...

Страница 5: ...its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shal...

Страница 6: ...ECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURER S WARRANTY DAMAGES RESULT...

Страница 7: ...perate fixture if the power cord is frayed crimped damaged and or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease NEVER force a power cord connect...

Страница 8: ...8 OVERVIEW POWER IN DMX IN 3 PIN DMX OUT 3 PIN Power Out System Menu LCD Controls S Knobs to tighten Brackets Yokes Mounting Brackets Yokes Lens FUSE DMX OUT 3 PIN DMX IN 5 PIN...

Страница 9: ...ce a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture clamps cables and a...

Страница 10: ...d through the center hole of the closed dual yokes The dual yokes of the fixture provides a rigging point for a SAFETY CABLE not included Be sure to only use one of the designated rigging points for t...

Страница 11: ...ncluding among others calculating working load limits installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do n...

Страница 12: ...ssigned to address 1 to that fixture no matter where it is located in the DMX chain The SIXPAR 300 can be controlled via DMX 512 protocol and the DMX address is set via the control menu DMX Cable REQU...

Страница 13: ...ll the fixtures simultaneously If a different DMX address is set for each fixture each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channe...

Страница 14: ...e DMX512 system becomes bi directional allowing a compatible RDM enabled controller to send out a signal to devices on the wire as well as allowing the fixture to respond known as a GET command The co...

Страница 15: ...06 07 08 or 12 Pressing the ENTER button once will confirm your selected value Exit at any time without making any adjustments by pressing the MODE button INFORMATION DISPLAYED DURING INITIAL POWER O...

Страница 16: ...00 99 B00 99 Adjust BLUE Brightness 00 99 W00 99 Adjust WHITE Brightness 00 99 A00 99 Adjust AMBER Brightness 00 99 U00 99 Adjust UV Brightness 00 99 S00 99 Adjust STROBE SPEED 00 SLOW 0 1Hz 99 FAST...

Страница 17: ...17 DIMMER MOD E...

Страница 18: ...STROBE 128 159 Strobe Pulse Effect in Sequence SLOW to FAST 160 191 LED ON NO STROBE 192 223 Random Strobe Effect SLOW to FAST 224 255 LED ON NO STROBE 9 COLOR MACROS 0 3 OFF 4 7 RED 8 11 GREEN 12 15...

Страница 19: ...88 191 RED GREEN AMBER UV 192 195 RED BLUE WHITE AMBER 196 199 RED BLUE WHITE UV 200 203 RED BLUE AMBER UV 204 207 RED WHITE AMBER UV 208 211 GREEN BLUE WHITE AMBER 212 215 GREEN BLUE WHITE UV 216 219...

Страница 20: ...ion service technician Should you need any spare parts please order genuine parts from an authorized Elation dealer Please refer to the following points during routine inspections A detailed electric...

Страница 21: ...ol Panel LCD Menu Display 3 5pin DMX Twist Locking Power Cable With Wired Digital Communication Network SIZE WEIGHT Length 14 4 365mm Width 4 9 125mm Vertical Height 14 4 365mm Weight 18 0 lbs 8 1 kg...

Страница 22: ...22 DIMENSION S Drawings not to scale Specifications and improvements in the design of this unit and this manual are subject to change without notice PHOTOMETR IC DATA...

Страница 23: ...nt or relocate the device increase the separation between the device and the receiver Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected Consu...

Страница 24: ......

Отзывы: