SYSTEM MENU

ON-BOARD SYSTEM MENU

The 

SIXPAR 300™

 comes with an easy to navigate system menu. The next sections will cover 

how to access each menu function.

LCD CONTROL PANEL DISPLAY

The (4) button control panel (see image below) located on back of the fixture allows you to 

access the main menu and make all necessary adjustments to the 

SIXPAR 300™

.

During normal operation, pressing the 

MODE

 button will navigate through the different function 

menus. Once you reach a desired menu, press the 

ENTER

 button to select that menu. The 

variable field that can be adjusted within the selected menu will begin to flash. Using the 

UP

 or 

DOWN

 buttons, adjust the field until the desired value is displayed. For example, the 

CHANNEL 

CH

: menu variable field can be set to 

06

07

08

, or 

12

. Pressing the 

ENTER

 button once will 

confirm your selected value. Exit at any time without making any adjustments by pressing the 

MODE

 button.

INFORMATION DISPLAYED DURING INITIAL POWER ON

When the fixture is initially powered 

ON

, the display shows the following information:

Update

Wait...

SIXPAR

300

300

V1.14

*Fixture Software Version (≥)

LCD CONTROL PANEL LOCKOUT

When the 

Display ON

 menu is set to 

OFF1

, the LCD display will turn OFF after 30 seconds and 

the (4) button Control Panel will be LOCKED. To unlock the (4) button LCD control panel follow 

these steps:

1.  When locked, the display will show: 

LOCKED*****

2.  Press 

UP

, then the display will change to: 

LOCKED****

 (one * disappears)

3.  Press 

DOWN

, then the display will change to: 

LOCKED***

 (two * disappear)

4.  Press 

UP

, then the display will change to: 

LOCKED**

 (three * disappear)

5.  Press 

DOWN

, then the display will change to: 

LOCKED*

 (4 * disappear)

6.  Press 

ENTER

, then the display will change to 

LOCKED

 and then become unlocked

Содержание SIXPAR 300

Страница 1: ...SIXPAR 300 user manual...

Страница 2: ...economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging a...

Страница 3: ...arranty USA Only 5 Safety Guidelines 6 Overview 8 Installation 9 DMX Setup 12 RDM Setup 14 System Menu 15 Dimmer Mode 17 DMX Channel Functions and Values 18 Maintenance Guidelines 20 Specifications 21...

Страница 4: ...upport team for further instructions Please do not return this device to your dealer without first contacting customer support Please do not discard the shipping carton in the trash Please recycle whe...

Страница 5: ...its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shal...

Страница 6: ...ECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURER S WARRANTY DAMAGES RESULT...

Страница 7: ...perate fixture if the power cord is frayed crimped damaged and or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease NEVER force a power cord connect...

Страница 8: ...8 OVERVIEW POWER IN DMX IN 3 PIN DMX OUT 3 PIN Power Out System Menu LCD Controls S Knobs to tighten Brackets Yokes Mounting Brackets Yokes Lens FUSE DMX OUT 3 PIN DMX IN 5 PIN...

Страница 9: ...ce a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture clamps cables and a...

Страница 10: ...d through the center hole of the closed dual yokes The dual yokes of the fixture provides a rigging point for a SAFETY CABLE not included Be sure to only use one of the designated rigging points for t...

Страница 11: ...ncluding among others calculating working load limits installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do n...

Страница 12: ...ssigned to address 1 to that fixture no matter where it is located in the DMX chain The SIXPAR 300 can be controlled via DMX 512 protocol and the DMX address is set via the control menu DMX Cable REQU...

Страница 13: ...ll the fixtures simultaneously If a different DMX address is set for each fixture each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channe...

Страница 14: ...e DMX512 system becomes bi directional allowing a compatible RDM enabled controller to send out a signal to devices on the wire as well as allowing the fixture to respond known as a GET command The co...

Страница 15: ...06 07 08 or 12 Pressing the ENTER button once will confirm your selected value Exit at any time without making any adjustments by pressing the MODE button INFORMATION DISPLAYED DURING INITIAL POWER O...

Страница 16: ...00 99 B00 99 Adjust BLUE Brightness 00 99 W00 99 Adjust WHITE Brightness 00 99 A00 99 Adjust AMBER Brightness 00 99 U00 99 Adjust UV Brightness 00 99 S00 99 Adjust STROBE SPEED 00 SLOW 0 1Hz 99 FAST...

Страница 17: ...17 DIMMER MOD E...

Страница 18: ...STROBE 128 159 Strobe Pulse Effect in Sequence SLOW to FAST 160 191 LED ON NO STROBE 192 223 Random Strobe Effect SLOW to FAST 224 255 LED ON NO STROBE 9 COLOR MACROS 0 3 OFF 4 7 RED 8 11 GREEN 12 15...

Страница 19: ...88 191 RED GREEN AMBER UV 192 195 RED BLUE WHITE AMBER 196 199 RED BLUE WHITE UV 200 203 RED BLUE AMBER UV 204 207 RED WHITE AMBER UV 208 211 GREEN BLUE WHITE AMBER 212 215 GREEN BLUE WHITE UV 216 219...

Страница 20: ...ion service technician Should you need any spare parts please order genuine parts from an authorized Elation dealer Please refer to the following points during routine inspections A detailed electric...

Страница 21: ...ol Panel LCD Menu Display 3 5pin DMX Twist Locking Power Cable With Wired Digital Communication Network SIZE WEIGHT Length 14 4 365mm Width 4 9 125mm Vertical Height 14 4 365mm Weight 18 0 lbs 8 1 kg...

Страница 22: ...22 DIMENSION S Drawings not to scale Specifications and improvements in the design of this unit and this manual are subject to change without notice PHOTOMETR IC DATA...

Страница 23: ...nt or relocate the device increase the separation between the device and the receiver Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected Consu...

Страница 24: ......

Отзывы: